Volvo EC18 Electric Electrical System Decommissioning and Commissioning

This instruction show you guide on how to decommission and commission electrical system for Volvo EC18 electric.

 

Related Conetents:

2024 Volvo  TechTool PTT 2.8.241 APCI 0.7.1.0/2.7.116 All Version Free Download

Volvo PROSIS 2023 2019 2018 Parts Catalog & Repair Manuals Free Download

Volvo Diagnostic Kit (88890300)

Volvo VOCOM 88890300 Diagnostic Kit

 

Procedures:

Protective gloves in different sizes are available as special tools.

A check of the measuring equipment must be carried out prior and after to measurement to ensure that valid values are measured. The review must be done on an independent system under known conditions.

 

The operation must only be carried out by personnel with adequate training to safety regulations.

1.Check the personal protective equipment prior to the work activity.

2.Establish a work location and place the machine in the defined area.

 

Decommissioning

3.Place machine in the service position.

4.Disconnect all charging equipment. See the instruction in the operator manual.

5.Turn the battery disconnect switch to the off position and secure it against restarting.

 

NOTE!

Use a LOTO device to secure the battery disconnect switch.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (1)

Figure 1
Battery disconnect switch

6.Open the rear hood (5).

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (2)

Figure 2
Covers

7.Remove the upper (2) and lower (1) left side cover.

8.Disconnect the cable from the negative (-) battery terminal (1).

 

NOTE!

It takes up to 10 minutes to discharge the electric energy.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (3)

Figure 3
Battery

Negative (-) battery terminal

Positive (+) battery terminal

9.Put on required personal protective equipment.

10.Remove the cover of the fuse box.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (4)

Figure 4
Fuse box

11.Measure the voltage free condition between the positive (+) cable (1) connected to the fuse box and the frame ground point or the negative (-) connector at the fast charging connector. Use 88830641 Test unit

 

NOTE!

Observe the correct handling of the test unit.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (5)

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (6)

 

Figure 6
Fast charging connector

Negative (-) connector

Due to the compact installation situation of the batteries, there are two options to disconnect the supply voltage.

 

Variant 1

12.Remove the upper left side cover.

13.Disconnect the cables from the negative (-) battery connections (1).

 

NOTE!

Cover the connector of the cables to avoid undesired connection.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (7)

 

Figure 7
Traction batteries

14.Disconnect the cables from the positive (+) battery connections (2).

NOTE!

Cover the connector of the cables to avoid undesired connection.

Variant 2

 

NOTE!

Consider that the positive (+) cables up to the fuse box may under live voltage if a malfunction of a battery occurs.

 

NOTE!

Do not proceed any operation in the proximity of these cables and the fuse box.

15.Disconnect the positve (+) cable from the terminal (1), use a protective cap to isolate it.

 

NOTE!

Secure that the protective cap isolates the cable.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (8)

16.Install the fuse box cover and tighten the screws

17.Apply a sticker on the outside of the fuse box that mention the segregation takes place internally.

 

Commissioning

If not stated otherwise, follow the instructions below.

 

Variant 1

18.Install the cover of the fuse box.

19.Connect the cables to the positive (+) battery connections (2).

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (9)

Figure 9
Traction batteries

20.Connect the cables to the negative (-) battery connections (1).

 

Variant 2

21.Remove the cover of the fuse box.

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (10)

Figure 10
Fuse box

22.Remove the isolating protective cap on the cable.

23.Connect the positive (+) cable to the terminal (1). Tighten the screw of the terminal with recommended torque.

24.Install the cover of the fuse box.

25.Remove the applied sticker mentioning the segregation.

Common procedure

26.Connect the cable to the negative (-) battery terminal (1).

Volvo EC18 Electric Electrical System Decommissioning and Commissioning (11)

27.Close the covers.

28.Remove the LOTO device securing the battery disconnect switch.

29.Turn the battery disconnect switch to the on position.

30.Set the ignition switch to position 1.

 

NOTE!

Wait about 1 minute and check that no error messages appears.

Set the ignition switch to position 0.

 

For more Volvo excavator repair,please refer to Volvo excavator trouble repair