Categories: Auto Key Program

AVDI Diagnostics All Keys Lost Programming for Range Rover 2019

In this instruction,car-auto-repair.com will show you guide on how to use AVDI diagnostics to do all keys lost programming for 2019 Range Rover.

 

Software used:

Abrites Diagnostics for Jaguar/Land Rover

AMS- Annual Maintenance Subscription

JL005 Key learning(2018+)

 

Hardware used:

AVDI – Abrites Vehicle Diagnostic Interface

ZN002 Pro Tag

CB012 Cable Set

TA57 ABRITES JLR Key for 2018+ vehicles(433MHz)

 

Procedure:

Entering the car will trigger the alarm. Once keys are programmed it can be stopped.

Connecting AVDI to the OBD

Connecting the CB012 adapter cable to the AVDI

If a working key is present, CB012 and direct CAN-H and CAN-L connection are not required.

Also if the car is not armed, CB012 and a direct connection are once again not required

The needle connectors are connected to the CAN-H and CAN-L of the car. CAN-H is the yellow/red cable and CAN-L is the yellow/brown(yellow/purple)

The cables are located under the driver’s seat(or passenger’s seat/inside all 4 doors)

This is what the cables look like

Starting the procedure in the JLR software

For the procedure I’m using two abrites TA57 keys, both are new and won’t start the car

ZN002 Pro Tag is also required for the procedure

Enter the “Key Learning Special” menu

Click “OK”

Place one of the TA57 on the ProTag

Now place the 1st key on the ProTag

Placing the 2nd Key

Until programming completed.

Programming is done.

If you want to know more about Range Rover, please refer to Range Rover Trouble Repair.

Kevin

Recent Posts

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

8 hours ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

2 days ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

2 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

4 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

4 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

5 days ago