Bendix EC-80 Cartridge Lifetime Prediction Reset Test by JPRO

Here is the instruction show you guide on how to perform Cartridge lifetime prediction reset for Bendix EC-80 by JPRO Diagnostic Software.This test provides the ability to reset the Cartridge Lifetime Remaining value to 100% after a new air dryer cartridge has been installed.

 

Related Contents:

2024 JPRO Noregon Commercial Fleet Diagnostics Free Download

Noregon JPRO DLA+ 2.0 Adapter

 

Procedures:

1 Select Cartridge Lifetime Prediction Reset Test and press Enter or the Start Button.

2 The test dialog will be displayed.

NOTE: Reset should only be performed after a new air dryer cartridge has been installed.
3 Click the Reset button to reset the Cartridge Lifetime Remaining value to 100%. The Wetness Level and Total Air Delivered values will also be reset.
4 Selecting Additional Info will display important test and repair information, including explanations for related faults. Click Exit to close this screen.

 

Cartridge Lifetime Prediction Reset Information:

The CLP Reset should only be performed after a new air dryer cartridge has been installed. Resetting the CLP without changing the cartridge can lead to moisture and water in air system.

Cartridge Lifetime Remaining (SPN 13073) indicates between 100% for a fresh cartridge to 0% for

an expired cartridge. After CLP Reset is performed, Cartridge Lifetime Remaining will read 100%.

 

For specific instructions, see AD-HFi Service Data Sheet SD-08-12046.

The following faults are the ones related to Cartridge Lifetime Prediction and the actions to take:

Cartridge maintenance prediction pre-worn alert (Flash Code 30-1), SPN 521610, FMI 15:

This indicates the cartridge is approaching its lifetimne limit (15% lifetimne remaining or less).

Cartridge may be replaced and CLP Reset run.

 

Cartridge maintenance prediction nominal alert (Flash Code 30- 2), SPN 52610, FMI 16:

This indicates the cartridge has reached its lifetime limit or 0% lifetime remaining. Cartridge must be replaced and CLP Reset run.

 

Cartridge maintenance prediction over-worn alert (Flash Code 30-3), SPN 521610, FMI 0:

This indicates that the cartridge has been in service beyond its service lifetime. This fault also

indicates there may be water in the air system. Check reservoirs for water via drain check valves and service accordingly. Cartridge must be replaced and CLP Reset run.

 

5 When done, press the Exit button to return to the test selection dialog.

More topics about JPRO Diagnostic,please refer to:JPRO Diagnostics Guide

auto

Recent Posts

Volvo and Mack EPA 10 Engine Hydrocarbon Dosing Control Valve Test by JPRO

This instruction show you guide on how to perform hydrocarbon dosing control valve test for…

3 days ago

Fendt Tractor SPN 100 FMI 31 Oil Pressure Sensor Defect Solution

This instruction show you guide on how to solve Fendt tractor SPN 100 FMI 31…

4 days ago

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure   Related Contents: 2024.06 Detroit Diesel…

6 days ago

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.…

1 week ago

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout   Vehicles: Monza, Kadett and…

1 week ago

How to Remove Oil Pressure Regulation Valve for CLAAS AXION 950

This illustration show you guide on how to remove oil pressure regulation valve for CLAAS…

1 week ago