BMW F25 F26 Engine Intermittently Will Not Start at Very Low Outside Temperatures

BMW engine will not start at times at very low outside temperatures (-4°F/-20°C and colder); however, the battery state of charge is correct and the starter turns the engine over properly.This starting difficulty is most likely to occur after shutting the engine off briefly for 5 or 10 minutes, such as when refueling.

The following faults are most likely stored in the DME:

N20 engine:

  • 1B5202 – Terminal 15N_1: No voltage
  • 1B5302 – Terminal 15N_2: No voltage
  • 1B5402 – Terminal 15N_3: No voltage

N52T engine:

  • 1B5102 – Terminal 15N_3: line from CAS, electric: short circuit to earth
  • 1B5501 – Terminal 15N: No voltage
  • 1F0601 – Terminal 15N from CAS, switching delay: Switches too late

N55 engine:

  • 1B5202 – Terminal 15N_1: No voltage
  • 1B5302 – Terminal 15N_2: No voltage
  • 1B5402 – Terminal 15N_3: No voltage

 

In addition, other engine electronic power supply-related faults could be stored for components such as VANOS solenoids, camshaft sensors, engine oil pressure sensor, engine oil pressure control valve, engine oil level sensor, etc.

 

CAUSE

At very low outside temperatures, low levels of moisture present inside the power distribution module (PDM) can freeze the internal micro-relay contacts.

 

CORRECTION

F25 and F26

Replace the PDM module and install the cover (if not already present) with the plastic rivet.

 

Important:

Follow the instructions in the attachment. This will help ensure that the power supply wiring does not contact the cover.

 

F15 and F16

Replace the PDM module and install the cover (if not already present) using the existing mounting screw.

 

Important!

The replacement PDM module part number listed below is only to be used in the case of a failure at very low ambient temperatures, as described above.

All other repairs requiring a PDM replacement must be done using P/N 12 63 7 591 534 and/or as specified in ETK

auto

Recent Posts

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

1 day ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

3 days ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

6 days ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

1 week ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

2 weeks ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

3 weeks ago