After Bobcat CW L85 compact wheel loader brake pedal sensor replacement/drive controller replacement,then Reason for Calibration A calibration procedure must be performed whenever
Brake Calibration Procedure
1.The ignition must be ON
2.The engine must be ON
3.The vehicle must be stopped
4.The travel direction switch must be in neutral
5.Follow the Service Analyser instructions to complete the calibration procedure.
Press the “Run calibration” Button
Press the “start” button
Slowly press and release the brake pedal fully 2 times
The screen will notify if the calibration is successful or not: “Calibration Passed” or “Calibration Failed” If the Calibration fails, service analyser will list potential causes for the failure
Press the “finish” Button
Note: on any procedure when the engine is NOT running, low battery voltage will cause erratic readings or failed calibration. Always perform with a fully charged battery.
More Bobcat excavator repair,please refer to:Bobcat excavator repair.
Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…
Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…
Here is the illustration show you guide on how to solve Perkins 1106D electric power…
Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…
This instruction show you guide on how to perform No load max differential pressure measurement…
Here is the instruction show you guide on how to solve Doosan machine P02EB over…