Bobcat SSL A300 Skid Steer Actuator Calibration Guide

A calibration procedure will need to be performed whenever;a handle or travel pedal sensor is replaced,a work group valve, or the actuator is replace and if an ACS controller is replaced.More Bobcat excavator repair,please refer to:Bobcat excavator repair.

2023 Bobcat Service Analyzer 91.15 91.05 Diagnostic Free Download

Actuator Testing Excessive actuator loading can occur if the actuator and valve spool components are misaligned. Misalignment may reduce spool stroke performance and reduce the life of the actuator. Starting with software version 36, the Bobcat Service Analyzer will be able to perform tests to diagnose actuator and valve spool misalignment.

 

NOTE:Warm the hydraulic fluid to room temperature 22℃(72F), stop the engine and clear all active service codes before running the test.

 

Once the test is initiated, an automatic calibration sequence will start. When calibration is complete,a test will be performed and the results can be viewed on the Bobcat Service Analyzer screen.

 

This test will engage both actuators to fully stroke the spools then allow the centering springs to return the spools toneutral. Next, both actuators are engaged to move the spools just past the neutral points then allow the centering springs to return the spools to neutral.

 

When complete, the Actuator Test will show a pass mode or fail mode. The pass mode indicates that no problems were detected. The fail mode indicates one or a combination of three problems below.

 

Actuator slow return to neutral. The spool returns to neutral too slowly.

Actuator did not fully extend/retract. During the test, the spool was not able to fully stroke in both directions.

Actuator out of neutral. The spool did not return to the neutral window during the test.

NOTE:A time out will occur if the test cannot be completed within 8 seconds. If this happens, retry the test.

If the initial Actuator Test results in a fail mode due to a slow return to neutral, follow the troubleshooting tree to pinpoint the probable cause.

If the Actuator Test fails after the hydraulic fluid is warmed, go to the next step and loosen the bolts that mount the actuator to the control valve. Loosen the bolts just enough so the actuator can be moved slightly up/down or side/side.

Rerun the Actuator Test, if the test passes, check the following probable causes in Column 1Check the probable causes in the order they are listed.

Repairing one cause may be all that is required. Re-run the test to verify.

NOTE:Actuator and spool misalignment. Re-tighten the two bolts evenly, turn the first bolt oneturn, then turn the other bolt one turn until both bolts are tight.

 

If the Actuator Test failed due to a slow return to neutral after checking the probable causes in Column 1[ Figure 1], check the following probable causes in Column 2[ Figure 1].

Contamination in the spool.

The spool end cap may be defective or the centering spring may be broken. Inspect the end cap and the centering spring, replace if necessary.

The wire harness or connectors may have an intermittent short. Inspect the connections and wire hamesses.

The controller may be defective, replace the controller.

If the initial Actuator Test results in the fail mode actuator did not fuly extend /retract, check the following.

The actuator connectors may be reversed between the lift and tilt actuator. Reverse the connectors and rerun the Actuator Test.

The actuator may be weak, replace the actuator.

The spool end cap may be defective or the centering spring may be broken. Inspect the end cap and the centering spring, replace if necessary.?Contamination in the spool.

If the initial Actuator Test results in the fail mode actuator out of neutral, check the following.

 

The actuator connectors may be reversed between the lift and tilt actuator. Reverse the connectors and rerun the Actuator Test.

The actuator may be weak, replace the actuator.

The spool end cap may be defective or the centering spring may be broken. Inspect the end cap and the centering spring, replace if necessary.?Contamination in the spool.

If the initial Actuator Test results in the fail mode actuator out of neutral, check the following.

The actuator may be defective, replace the actuator.

The spool end cap may be defective or the centering spring may be broken. Inspect the end cap and the centering spring, replace if necessary.?Contamination in the spool.

 

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

7 days ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

1 week ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago