Here is my blog reader feedback on how to use DDDL diagnostic to reset/clean PDF data or ash accumulator value for 3720/15 fault code.
Preparations:
2024.06 Detroit Diesel Diagnostic Link DDDL 8.20 8.09 Free Download
Detroit Diesel Diagnostic Link DDDL 8.20 Professional with (10 10 10) Level Installation Service
Procedures:
Click “Troubleshooting” button,it will show you with detail information:
SPN 3720/FMI 15-EPA07-EPA07-EPA10-GHG14
Diesel Particulate Filter Has Reached the End of its Service Life.
Replace DPF and perform the Ash Accumulator reset using DiagnosticLink
The DPF lamp will illuminate and code 2730/15 will log when the truck reaches the appropriate mileage interval.This fault indicate that the DPF need to be replaced.The DPF Ash Accumulator Routine in Diagnostic Link must be completed.This routine can be found in the Actions drop-down menu and must be completed…
Select “Actions”–>”Aftertreatment”–>”DPF Ash Accumulator”
Now it show you with below panel,use this panel to reset or synchronize the ash volume ratio.
Select “Cleaned or remanufactured filter installation”
Then input two serial number for the aftertreatment system now installed on below.
After then click “Set Ash Volume”
Wait for procedures completing.
Done!
It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…
Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…
This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…
Here is the instruction show you guide on how to install the left-hand drum bearing…
This instruction show you guide on how to remove and replace loader lift ram for…
This instruction show you guide on how to solve Caterpillar C9 engine 31 84-1 fault…