To run the routine:

1 Navigate to the DPF System Panel, under Service Routines. Open the drop-down window and select the Perform Performance Check – Low Temp ATD.

2 Start the service routine. The engine speed will increase to 1250 rpm for this routine.

3 Once the engine coolant temperature reaches 50°C (126°F), the engine brake will activate (100% PWM).

4 The system will continue to warm up. Once the DOC inlet temperature reaches 270°C (518°F), the HC dosing system will turn on. The HC dosing system will perform its safety check with no HC dosing. The Fuel Doser Injection Status (in yellow) will go to 100%, then back to 0% for the remainder of the routine.

5 Navigate to the SCR Service Routines Panel. The DOC Inlet, DOC Outlet, DPF Outlet, SCR Inlet (calculated value based on DPF outlet and SCR outlet on the 1-BOX) and SCR Outlet temperatures should stabilize in the mid-to-upper 375°C (700°F) range.

6 Once the temperatures stabilize (should occur within 25 to 30 minutes into the service routine), compare all temperature sensor values. They should read within 27°C (45°F) of each other. If the values are outside the 27°C (45°F) range, the temperature sensor has possibly drifted high or low.

7 The service routine will automatically stop after 30 minutes.

 

More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair

auto

Recent Posts

How to Solve CASE 7120 IH 20 Series Axial-Flow Combine Creep Problem

Here is the instruction show you guide on how to solve CASE 7120 IH 20…

1 day ago

How to Jump-start Engine for MANITOU MT6034 Construction Telehandler

If the battery becomes discharged or does not have enough power to start the engine,…

4 days ago

Liebherr Machine P1121 DEF Pump Out of Service Error Solution

Here is the instruction show you guide on how to solve Liebherr machine trouble code…

7 days ago

AGCO Machine Trouble Code SPN 1136 ECU Temperature NO SIGNAL

This instruction show you guide on how to solve AGCO machine trouble code SPN 1136…

1 week ago

How to Solve JCB JS140/205/215 Machine P2280-00 Air Filter Blocked

This instruction show guide on how to solve JCB JS140/205/215 machine trouble code P2280-00 air…

2 weeks ago

MANITOU MT6034 Telehandlers PWP System Deactivation Tests

This instruction show you guide on how to do deactivation test for MANITOU MT6034 telehandlers…

3 weeks ago