Detroit Diesel GHG14 DDEC VI Engine Regeneration Troubleshooting

This is an instruction show you guide on how to do regeneration troubleshooting for Detroit Diesel GHG14 DDEC VI engine.

 

Related Contents:

2024 Detroit Diesel Diagnostic Link DDDL 8.19 8.09 Free Download

JPRO DLA+ 2.0 Adapter

NEXIQ USB Link Adapter

 

 

Procedures:

Note : This diagnostic should be completed first for regeneration issues.

Verification: Verify Parked Regeneration Completes

1.Connect using DiagnosticLink ®  and then turn the ignition ON (key ON, engine OFF).

2.Using DiagnosticLink, check for fault codes. Are any Fuel System or Air System fault codes present?

2a Yes; troubleshoot those codes first.

2b No; Go to step 3.

 

WARNING  

HOT EXHAUST

During parked regeneration the exhaust gases will be extremely HOT and could cause a fire if directed at combustible materials. The vehicle must be parked outside.

 

Note : If the unit is in zone zero, the system will not initiate a parked regeneration without using DiagnosticLink.

 

3.Using DiagnosticLink, go to Service Routines/DPF System/Perform Parked Regeneration/Start. Does the regeneration start successfully by reaching at least 1,100 rpm?

3a Yes; let the regeneration continue to run and Go to step 4.

3b No; Regeneration – Unable to Start a Parked Regeneration

 

4.Does the regeneration end at any time without a fault code coming active?

4a Yes; Regeneration – Regeneration Ends Abruptly.

4b No; Go to step 5.

 

5.Using DiagnosticLink, monitor DOC inlet temperature. Does the DOC inlet temperature reach 280 °C (536 °F)?

5a Yes; Go to step 6.

5b No; Regeneration – DOC Inlet Temperature Unable to Reach HC Dosing Temperature .

 

6.Using the chart tab in DiagnosticLink, monitor DOC outlet temp and DOC Out Model Delay. After 30 minutes into the regeneration, is there a difference greater than +/- 55.5°C (100°F)?

6a Yes; Regeneration – DOC Outlet Temperature Unable to Meet Model Delay .

6b No; Go to step 7.

 

7.Using the chart tab in DiagnosticLink, monitor AS077: Fuel Cut Off Valve. At 30 minutes, does Fuel Cut Off Valve stay steady at 100%?

7a Yes; troubleshooting is complete.

7b No; stop the parked regen and start a DOC Face Cleaning service routine, found under Action – Aftertreatment. Let the routine run for one minute, then stop it. Start another parked regen and verify it completes successfully.

 

More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair

auto

Recent Posts

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

1 day ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

3 days ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

6 days ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

1 week ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

2 weeks ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

3 weeks ago