Detroit Diesel GHG14 DDEC VI Engine Regeneration Troubleshooting

This is an instruction show you guide on how to do regeneration troubleshooting for Detroit Diesel GHG14 DDEC VI engine.

 

Related Contents:

2024 Detroit Diesel Diagnostic Link DDDL 8.19 8.09 Free Download

JPRO DLA+ 2.0 Adapter

NEXIQ USB Link Adapter

 

 

Procedures:

Note : This diagnostic should be completed first for regeneration issues.

Verification: Verify Parked Regeneration Completes

1.Connect using DiagnosticLink ®  and then turn the ignition ON (key ON, engine OFF).

2.Using DiagnosticLink, check for fault codes. Are any Fuel System or Air System fault codes present?

2a Yes; troubleshoot those codes first.

2b No; Go to step 3.

 

WARNING  

HOT EXHAUST

During parked regeneration the exhaust gases will be extremely HOT and could cause a fire if directed at combustible materials. The vehicle must be parked outside.

 

Note : If the unit is in zone zero, the system will not initiate a parked regeneration without using DiagnosticLink.

 

3.Using DiagnosticLink, go to Service Routines/DPF System/Perform Parked Regeneration/Start. Does the regeneration start successfully by reaching at least 1,100 rpm?

3a Yes; let the regeneration continue to run and Go to step 4.

3b No; Regeneration – Unable to Start a Parked Regeneration

 

4.Does the regeneration end at any time without a fault code coming active?

4a Yes; Regeneration – Regeneration Ends Abruptly.

4b No; Go to step 5.

 

5.Using DiagnosticLink, monitor DOC inlet temperature. Does the DOC inlet temperature reach 280 °C (536 °F)?

5a Yes; Go to step 6.

5b No; Regeneration – DOC Inlet Temperature Unable to Reach HC Dosing Temperature .

 

6.Using the chart tab in DiagnosticLink, monitor DOC outlet temp and DOC Out Model Delay. After 30 minutes into the regeneration, is there a difference greater than +/- 55.5°C (100°F)?

6a Yes; Regeneration – DOC Outlet Temperature Unable to Meet Model Delay .

6b No; Go to step 7.

 

7.Using the chart tab in DiagnosticLink, monitor AS077: Fuel Cut Off Valve. At 30 minutes, does Fuel Cut Off Valve stay steady at 100%?

7a Yes; troubleshooting is complete.

7b No; stop the parked regen and start a DOC Face Cleaning service routine, found under Action – Aftertreatment. Let the routine run for one minute, then stop it. Start another parked regen and verify it completes successfully.

 

More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair

auto

Recent Posts

How to Solve Allison 3000 & 4000 Gen5 Engine Trouble Code P0703

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…

2 days ago

How to Solve Fendt MT1149 Tractor SCR System Emptying Not Completed

Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…

1 week ago

How to Set Play Between Timing Pinion Teeth for CLAAS AXION 920 Tractor?

Here is the instruction show you guide on how to set play between timing pinion…

1 week ago

Perkins 1106D Generation Injector Data Incorrect Test Guide

Perkins 1106D Generation Injector Data Incorrect Test Guide   Preparations: Perkins EST 2024A & 2023A…

1 week ago

How to Solve Deutz EMR3 Engine Error 16/108/APSCD Trouble

This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…

2 weeks ago

Kubota L4701 High Pressure Relief Valve Pressure Checking

Here show guide on how to check high pressure relief valve pressure for Kubota L4701…

2 weeks ago