This instruction show you guide on how to solve Detroit GHG14 EPA07 engine idle does not go into continuous run mode under extreme ambient conditions.
Preparations:
2024.06 Detroit Diesel Diagnostic Link DDDL 8.20 8.09 Free Download
Procedures:
Check as follows:
1Does the HVAC work on the vehicle?
1a Yes; Go to step 2.
1b No; repair the HVAC system first. Refer to chassis OEM guidelines.
2 Check CPC parameters to make sure the Continuous Run feature is enabled
2a Yes; Go to step 3.
2b No; this feature is available but not set up on the vehicle.
3 Is the Optimized Idle Thermostat Skin Temperature sensor properly adhered onto an outside metal wall, secured and wired to the Thermostat? Refer to OEM literature for sensor location.
3a Yes; Go to step 4.
3b No; repair as necessary.
4 Disconnect the Optimized Idle Thermostat electrical connector and measure the resistance between the Optimized Idle Thermostat connector and the Skin Temperature sensor harness side connector. Is the resistance less than 10 ohms?
4a Yes; replace the Skin Temperature sensor.
4b No; repair the circuit.
More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair
Detroit DD13 EPA10 (2010-13) trouble code SPN 84 FMI 13 (MCM) J1939 Wheel-based vehicle speed…
This instruction show you guide on how to solve Caterpillar C9 engine trouble code 36…
Kubota L3301 L3901 Excavator Safety Valve Setting Pressure Test Using Injection Nozzle Tester 1 Remove…
JCB Engine Fault Derate When a fault is detected, the ECU determines the severity of…
Here is a instruction show you guide on how to solve Liebherr ECU 2 D966…
AGCO EEM5 DEF Suction Module Tank sensor (CAN) The DEF suction module with the CAN-bus…