Detroit GHG14 EPA07 Engine High Crankcase Pressure Trouble Repair

This instruction should be used when Detroit GHG14 EPA07 engine high crankcase pressure.If the crankcase breather is leaking oil,pls go to diagnostic engine oil leaks.

Related Contents:

2024 Detroit Diesel Diagnostic Link DDDL 8.19 8.09 Free Download

JPRO DLA+ 2.0 Adapter

NEXIQ USB Link Adapter

 

 

Procedures:

1.Verify that the crankcase pressure is high; Refer to section “Crankcase Pressure Test” .

2Inspect the crankcase breather. Check for leaks at the inlet and outlet tubes, fittings, mounting surface to the cylinder block, and the housing-to-cap seal. Are there any external oil leaks present?

2a Yes; repair or replace the crankcase breather, if needed. Refer to section “Removal of the Crankcase Breather” and Go to step 8.

2b No; Go to step 3.

 

3.Is the vehicle slow at building air pressure?

3a Yes; Refer to section “Will Not Build Air Pressure or Slow to Build Air Pressure” .

3b No; Go to step 4.

 

WARNING

HOT EXHAUST

During parked regeneration the exhaust gases will be extremely HOT and could cause a fire if directed at combustible materials. The vehicle must be parked outside.

 

WARNING  

PERSONAL INJURY

Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

 

Always start and operate an engine in a well ventilated area.

  • If operating an engine in an enclosed area, vent the exhaust to the outside.
  • Do not modify or tamper with the exhaust system or emission control system.

Detroit Diesel Diagnostic Software

 

4.Perform a parked regen and observe DOC inlet pressure. Was the DOC inlet pressure above 8 kPa (1.2 psi) for a 1-Box or above 13 kPa (1.9 psi) for a 2-Box?

4a Yes; diagnose the cause for high DOC inlet pressure and verify the repair.

4b No; Go to step 5.

 

5Inspect the crankcase breather for an obstruction in the breather inlet passage and tube? Is an obstruction present?

5a Yes; clear the obstruction or replace the crankcase breather, if needed.

5b No; replace the crankcase breather, then Go to step 8.

 

6.Verify the repair by running a crankcase pressure test

Is the crankcase pressure high?

6a Yes; Go to step 7.

6b No; Go to step 8.

 

7.Was the crankcase breather replaced at any point during this procedure?

7a Yes; Go to step 8.

7b No; replace the crankcase breather. Go to step 8.

 

8.Perform a Relative Cylinder Compression Test;Did the Relative Cylinder Compression Test identify a possible suspect cylinder?

8a Yes; Go to step 9.

8b No; repair is complete.

 

9.Perform a Mechanical Cylinder Compression Test

Did the Mechanical Cylinder Compression Test pass?

9a Yes; replace the turbocharger and verify repair.

9b No; Refer to section “Symptom Diagnostics – Low Engine Compression” .

More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair

auto

Recent Posts

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

2 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

4 days ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

7 days ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

1 week ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

2 weeks ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

3 weeks ago