Doosan Engine Fault Code P060C ECU Hardware Com ROM Shut Off Path Error

This instruction show you guide on how to solve Doosan engine fault code ECU Hardware error – ECU Com ROM Shut off path error.

 

Preparations:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download

Doosan Diagnostic Tool

 

 

Trouble Code:P060C SPN 520619/520641/520642/520633/520654 FMI 12

Reason:

– Error in the plausibility of the function controller and the monitoring module.

– ECU internal communication error, ROM check error.

– Errors detected in the SPI communication.

– Error in the test of the shut-off path of the under/over voltage detection

Effect:SVS Torque Limit 0%

 

2) Circuit Description

ECU Internal Communication error and Hardware error

3) Component Location

ECU Internal

Doosan Engine Fault Code P060C ECU Hardware Com ROM Shut Off Path Error (1)

 

4) Condition for Running Diagnostic

Diagnosis component is processed in the alarm task raster or Diagnosis is preformed while post drive

 

5) Condition for Setting the Fault Code

If multiple errors are detected while testing

– Error in the plausibility of the function controller and the monitoring module.

– ECU internal communication error, ROM checks error.

– Errors detected in the SPI communication.

– Error in the test of the shut-off path of the under voltage detection.

– Error in the test of the shut-off path of the over voltage detection.

– Error in the test of the shut-off path of the monitoring module.

– Time out error trying to set or cancelling the alarm task

6) Condition for Clearing the Fault Code

None.

 

7) Check List

Doosan Engine Fault Code P060C ECU Hardware Com ROM Shut Off Path Error (2)

More topics for Doosan,please refer to:Doosan Trouble Repair

Visited 1 times, 2 visit(s) today