Heavy Equipment Repair

Doosan Engine P0087 Raid Pressure Physical Range Low Solution

Here is the instruction show you guide on how to solve Doosan engine P0087 SPN 520196 FMI12 rail pressure physical range low.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Doosan Diagnostic Tool

2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download

 

Code:

P0087 SPN 520196 FMI 1

 

Reason:

If the rail pressure falls below the limiting value based on the engine speed, this error will be detected.

 

Effect:

SVS Torque limit 0%

 

3) Condition for Running Diagnostic

– Engine running

4) Condition for Setting the Fault Code

– If the rail pressure falls below the limiting value based on the engine speed

 

5) Condition for Clearing the Fault Code
– If the rail pressure does not fall below the limiting value based on the engine speed
6) Check List

Step Inspection Standard
Value
YES NO
1 P0087 is raised on diagnostic tool? Step2
2 Check the battery voltage
Battery voltage is normal?
Step4 Step3
3 Change battery & Engine running
Problem fixed?
Problem fixed Step4
4 Check FIE system related faults or malfunction
If any, please refer to related manual & take action
Problem fixed?
Problem fixed Step5
5 Check if there is any leak in the FIE system
If there is any leak, fix or change that part
Problem fixed?
Problem fixed Step6
6 Change all FIE system
(CP-> Rail ->HPC & Injector)
For each part change, run engine and then check if the
fault disappear or not before next part change
Problem fixed?
Problem fixed Call Hot
line

 

auto

Recent Posts

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

21 hours ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

1 day ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

3 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

4 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

5 days ago

How to Perform Relative Cylinder Compression Test for Detroit GHG17 Engine

This illustration show you how to use Detroit Diesel Diagnostic Link diagnostic software to do…

6 days ago