Doosan Engine P0089 PRV Reached Maximum Allowed Opening Count

Here comes the solution for Doosan engine P0089 PRV reached maximum allowed opening count.

 

Preparation:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Doosan Diagnostic Tool

2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download

 

1) Overview

CODE P0089 SPN 520203 FMI 12

 

REASON

Monitoring the durability of the PRV (Opening time/count of PRV for wear out monitoring)

 

EFFECT

Torque limit : 0, 1 SVS

Doosan Engine P0089 PRV Reached Maximum Allowed Opening Count (1)

 

2) Circuit Description
Rail Pressure Signal: 236 Pin
Ground: 260 Pin
+5V supply: 211 Pin

3) Component Location

Doosan Engine P0089 PRV Reached Maximum Allowed Opening Count (2)

 

4) Condition for Running Diagnostic
Key on or Engine run

 

5) Condition for Setting the Fault Code
1. Opening count of PRV is more than 50 times
2. Forced to open the pressure relief valve performing a rail pressure shock according to the ECU logic
3. Forced to open the pressure relief valve performing rail pressure increase
4. PRV opening time is more than 50 times and is running engine for 300min
5. PRV opening time is longer than 300min

6) Condition for Clearing the Fault Code
1. Diagnostic Tester
2. Close the pressure relief valve performing rail pressure decrease

7) Check List

Step Inspection Standard
Value
YES NO
1 Change PRV(or Common Rail) and reset PRV parameter by
DDT

 

More topics for Doosan,please refer to:Doosan Trouble Repair

Visited 1 times, 1 visit(s) today