Doosan equipment machine relief pressure check guide,it must be performed for VBO calibration.
Preparations:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Relief pressure check
*Calibration judgement
5.1. Measure the input & output voltage of main pump pressure sensor
5.1.1. Check the output voltage when it is connected under unloaded condition.
5.1.2. Check the output voltage of the pilot pressure sensor while the machine is in operation.
(Take the DMS-5 monitoring data during the test)
5.1.3. Check if the voltage value measured at the pressure sensor is matched with the pressure indicated on the gauge panel.
5.1.4. Operate the machine and check if the pressure value indicated on the gauge panel is changed according to changes in the pressure.
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
*Operating voltage: 5V ± 5%, Output voltage: 1 ~ 5V, Operating current: max. 10 mA, measuring pressure: 0 to 500 bar, Measurement tolerance: ±5%
*Formula for voltage-pressure conversion: Voltage = (0.00816 x Pressure) + 1
5.2. Check the physical condition of the main pump pressure sensor
5.2.1. Assembly condition
5.2.2. External damage
5.2.3. Short circuit
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
5.3. Check the physical condition of the main relief valve on MCV
5.3.1. Assembly condition
5.3.2. Internal blockage
More topics for Doosan,please refer to:Doosan Trouble Repair
This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…