Doosan Machine Angle Sensor Check Guide

This instruction show you guide on how to do angle sensor check for Doosan machine.

 

Preparations:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Doosan Diagnostic Tool

 

Procedures:

Angle sensor check

*Calibration judgement

Depends on the model type. The criteria referred on DMS-5

 

2.1. Measure the input & output voltage of angle sensor in certain condition

Ex. DX350LC-7, outputs of angle sensor (Please refer the shop manual to check the exact value on each model)

  1. -45°: 0.5 V ±0.025V
  2. 0° : 2.5 V ±0.05V
  3. 45° : 4.5 V ±0.025V

*Operating voltage: 24V ±10%, Output voltage: 0.5V ~ 4.5V

 

2.2. Check the physical condition of angle sensor

2.2.1. Assembly condition

Contact type (ex. DX350LC-7)

1) Ensure that ball pin is guided in the nut of the spring collar in spring position. (Install the angle sensor with the electrical connection to the top.)

2) Center (rotate) the shaft of the swivel angle sensor between the stoppers like the position on the Figure

3) Check the groove/slot position of the sensor shaft in the controller (must not be horizontal) and set (rotate) and install the swivel angle sensor to groove/slot position.

4) Turn the angle sensor to adjust the signal of +4.5 V at the Q-max position of the rotary group and install the screw with the correct torque.

Non-contact type (ex. DX800LC-5B)

2.2.2. External damage

2.2.3. Short circuit

Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)

More topics for Doosan,please refer to:Doosan Trouble Repair

auto

Recent Posts

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

2 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

4 days ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

1 week ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

1 week ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

2 weeks ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

3 weeks ago