Here is a step by step guide on how to check main pump pressure sensor for Doosan machine.
Preparations:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Main pump pressure sensor check
*Calibration judgement
4.1. Measure the input & output voltage of main pump pressure sensor
4.1.1. Check the output voltage when it is connected under unloaded condition.
4.1.2. Check the output voltage of the pilot pressure sensor while the machine is in operation.
(Take the DMS-5 monitoring data during the test)
4.1.3. Check if the voltage value measured at the pressure sensor is matched with the pressure indicated on the gauge panel.
4.1.4. Operate the machine and check if the pressure value indicated on the gauge panel is changed according to changes in the pressure.
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
*Operating voltage: 5V ± 5%, Output voltage: 1 ~ 5V, Operating current: max. 10 mA, Measuring pressure: 0 to 500 bar, Measurement tolerance: ±5%
*Formula for voltage-pressure conversion: Voltage = (0.00816 x Pressure) + 1
4.2. Check the physical condition of the main pump pressure sensor
4.2.1. Assembly condition
4.2.2. External damage
4.2.3. Short circuit
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
More topics for Doosan,please refer to:Doosan Trouble Repair
This illustration show you guide on how to repair Cummings QSK60 CM2358 engine camshaft speed/position…
Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…
Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…
Here is the illustration show you guide on how to solve Perkins 1106D electric power…
Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…
This instruction show you guide on how to perform No load max differential pressure measurement…