Doosan E-Powerpack P3A02 cell over voltage fault trouble repair guide.
Related Contents:
Doosan e-Doctor 2.4.0.7 2023.06 100% Work
Doosan Heavy Duty Machine 2020 Service Manual Download
Reason:
Highest cell voltage > 4.25V
Module wire failure
Secondary BMS sensing problem
Effect:
Disable charge
Charge Power(W) = 0
Charge Current(A) = 0
1) Component Location:
<Cell wire>
Damaged somewhere
2) <Secondary BMS>
3) Condition for Running Diagnostic
During charging
4) Condition for Setting the Fault Code
Overcharge or abnormal cell voltage rise(Highest cell voltage > 4.25V)
5) Condition for Clearing the Fault Code
Operate the machine to discharge to the Highest cell voltage ≤ 4.15V
6) How to Solve Doosan E-Powerpack P3A02 cell over voltage
Step 1:
P3A02 is detected on service tool?
Reference value CV_HI>4.25V,Yes go to step 2
Step 2:
Disconnect the battery charger.
Operate the machine to discharge cell voltage in less
than 1 hr. Check the highest cell voltage(CV_HI) via
service tool.
Is P3A02 disappeared?
Reference value CV_HI<4.25V,Problem solved
More topics for Doosan,please refer to:Doosan Trouble Repair
MM0112 ABS Electronic Stability Brake Pressure Sensor Testing Related Contents: Meritor Wabco Toolbox v14.2…
Here is the instruction show you 3 methods to query car ECU models information correctly…
Here is an illustration show the details instruction on Kubota L3901 tractor engine sensors. …
This is an illustration on how to solve Massey Ferguson 6700 tractor SPN 29, FMI…
Here is the troubleshooting guide on how to solve HINO J05E engine 2018 P0045 DC…
Here is a solution for Allison 3000 & 4000 Gen 5 P0614 torque control mismatch…