Doosan P3A02 Cell Over Voltage Fault Trouble Repair

Doosan E-Powerpack P3A02 cell over voltage fault trouble repair guide.

 

Related Contents:

Doosan e-Doctor 2.4.0.7 2023.06 100% Work

Doosan Heavy Duty Machine 2020 Service Manual Download

 

Reason:

Highest cell voltage > 4.25V
Module wire failure
Secondary BMS sensing problem

 

Effect:

Disable charge
Charge Power(W) = 0
Charge Current(A) = 0

 

1) Component Location:

<Cell wire>
Damaged somewhere

2) <Secondary BMS>

 

3) Condition for Running Diagnostic
During charging

4) Condition for Setting the Fault Code
Overcharge or abnormal cell voltage rise(Highest cell voltage > 4.25V)

5) Condition for Clearing the Fault Code
Operate the machine to discharge to the Highest cell voltage ≤ 4.15V

 

6) How to Solve Doosan E-Powerpack P3A02 cell over voltage

Step 1:

P3A02 is detected on service tool?

Reference value CV_HI>4.25V,Yes go to step 2

 

Step 2:

Disconnect the battery charger.
Operate the machine to discharge cell voltage in less
than 1 hr. Check the highest cell voltage(CV_HI) via
service tool.
Is P3A02 disappeared?

Reference value CV_HI<4.25V,Problem solved

 

More topics for Doosan,please refer to:Doosan Trouble Repair

auto

Recent Posts

QSK60 CM2358 Engine Camshaft Speed/Position Sensor Data Erratic Incorrect

This illustration show you guide on how to repair Cummings QSK60 CM2358 engine camshaft speed/position…

4 days ago

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

6 days ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

1 week ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

1 week ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

1 week ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

1 week ago