Categories: ECU Chip Tuning

EDC16 Tuning Maps Guide

The EDC16 system is used in cars like the Seat Leon, golf 5 and other cars that are produced in the same period. The system looks a lot like the EDC15 system, but the EDC16 system is based on Torque (Nm) instead of Injected Quantity. There are a few more differences that are explained in this article. For all examples in this article I used the Seat Leon 105hp file.

 

Before starting Introduce,thanks to Midass selfless contribution to make this share.

 

Fuel related maps

  1. Drivers wish Maps:

General:

This map shows the required torque based on the RPM and the Throttle position. The output of this map is Torque in Nm. There may be more drivers wish maps, in the file I used for this guide there were 8 drivers wish maps.

Factors & offsets:

Map properties

Description:                  Torque

Unit:                               Nm

Name:                            Drivers wish

Start address:               1C2F96

Column x rows:           8×16

Values:                         16Bit(HiLo)

Factor:                          0.1

Offset:                          0

 

X-Axis

Description:                   Throttle position

Unit:                               %

Start address:                 1C2F86

Values:                           16Bit(HiLo)

Factor:                             0.01

Offset:                               0

 

Y-Axis

Description:                Rpm

Unit:                             1/min

Start address:              1C2F66

Values:                          16Bit(HiLo)

Factor:                           1

Offset:                            0

  1. Torque limiter:

General:

This map limits the torque of the engine based on RPM and atmospheric pressure. The output of this map is also Torque in Nm.

Factors & offsets:

Map properties

Description:                              Torque

Unit:                                           Nm

Name:                                       Torque limiter

Start address:                          1D43C2

Column x rows:                        21×3

Values:                                       16Bit(HiLo)

Factor:                                       0.1

Offset:                                       0

 

X-Axis

Description:                            Rpm

Unit:                                        1/min

Start address:                          1D4398

Values:                                      16Bit(HiLo)

Factor:                                       1

Offset:                                       0

 

Y-Axis

Description:                           Atmospheric pressure

Unit:                                        Hpa

Start address:                        1D4392

Values:                                 16Bit(HiLo)

Factor:                                  1

Offset:                                     0

 

  1. Nm to IQ conversion map:

General:

This map converts the requested Torque in Nm into IQ (injected quantity).

Factors & offsets:

Map properties

Description:                                IQ

Unit:                                             mg/stroke

Name:                                          Nm to IQ converion map

Start address:                             1D6F9A

Column x rows:                         16×15

Values:                                        16Bit(HiLo)

Factor:                                        0.1

Offset:                                         0

 

X-Axis

Description:                             Rpm

Unit:                                          1/min

Start address:                          1D6F7A

Values:                                     16Bit(HiLo)

Factor:                                      1

Offset:                                         0

 

Y-Axis

Description:                           Torque

Unit:                                        Nm

Start address:                       1D6F5C

Values:                                  16Bit(HiLo)

Factor:                                     0.1

Offset:                                    0

 

  1. Turbo map:

General:

This map set the required boost depending on the requested torque and current rpm. There might be more than one boost map. In this file there are 2 boost maps.

Factors & offsets:

Map properties

Description:                                    Boost

Unit:                                                 mBar

Name:                                              Boost map

Start address:                                1EAD92

Column x rows:                                10×16(the other map in this file is 10×15)

Values:                                            16Bit(HiLo)

Factor:                                             1

Offset:                                              0

 

X-Axis

Description:                                     Torque

Unit:                                                  Nm

Start address:                                 1EAD7E

Values:                                            16Bit(HiLo)

Factor:                                              0.1

Offset:                                               0

 

Y-Axis

Description:                                    Rpm

Unit:                                                 1/min

Start address:                                 1EAD5E

Values:                                              16Bit(HiLo)

Factor:                                             1

Offset:                                              0

 

  1. Turbo limiter map:

General:

This map limits the required boost depending on the atmospheric pressure and the current rpm.

Factors & offsets:

Map properties

Description:                                 Boost

Unit:                                              mBar

Name:                                           Boost limiter map

Start address:                            1EAF00

Column x rows:                            10×11

Values:                                          16Bit(HiLo)

Factor:                                            1

Offset:                                            0

 

X-Axis

Description:                                 Atmospheric pressure

Unit:                                             Hpa

Start address:                            1EAEEC

Values:                                       16Bit(HiLo)

Factor:                                          1

Offset:                                         0

 

Y-Axis

Description:                                Rpm

Unit:                                             1/min

Start address:                            1EAED6

Values:                                         16Bit(HiLo)

Factor:                                          1

Offset:                                          0

 

  1. Smoke limiter map:

General:

This map limits the IQ depending on airmass and the current rpm.

Factors & offsets:

Map properties

Description:                                              IQ

Unit:                                                            mg/stroke

Name:                                                        Smoke limiter map

Start address:                                            1D6188

Column x rows:                                         12×16

Values:                                                        16Bit(HiLo)

Factor:                                                        0.01

Offset:                                                         0

 

X-Axis

Description:                                            Boost

Unit:                                                        Mbar

Start address:                                        1D6170

Values:                                                     16Bit(HiLo)

Factor:                                                        1

Offset:                                                      0

 

Y-Axis

Description:                                           Rpm

Unit:                                                       1/min

Start address:                                       1D6150

Values:                                                  16Bit(HiLo)

Factor:                                                       1

Offset:                                                        0

 

  1. Single value boost limiter:

General:

This value limits the absolute pressure of the turbo. This value can be found by looking directly behind the turbo limiter map. If you look in 2D you see a series of bumps like this:

The Svbl is located at the end of the series of bumps, just before the line “falls” back to “0”. In this case it is the highest value between the turbo limitation map and the next map. The value of the Svbl in this file is 2350mBar.

 

Factors & offsets:

Map properties

Description:                                Single value boost limiter

Unit:                                            mBar

Name:                                          Svbl

Start address:                             1EB04A

Column x rows:                           1×1

Values:                                           16Bit(HiLo)

Factor:                                            1

Offset:                                               0

  1. Smoke limiter map:

General:

This map is a calibration map. This map shows how much rotation it takes to achieve the requered amount of fuel injected. the output of this map is in engine degrees.

Factors & offsets:

Map properties

Description:                                      Engine rotation

Unit:                                                  degrees

Name:                                              Duration map

Start address:                                    1E4F90

Column x rows:                               15×19

Values:                                            16Bit(HiLo)

Factor:                                               0.023437

Offset:                                                  0

 

X-Axis

Description:                                     IQ

Unit:                                                    mg/stroke

Start address:                                    1E4F72

Values:                                                16Bit(HiLo)

Factor:                                                0.01

Offset:                                                  0

 

Y-Axis

Description:                                       Rpm

Unit:                                                    1/min

Start address:                                       1E4F4C

Values:                                                16Bit(HiLo)

Factor:                                                 1

Offset:                                                  0

auto

Recent Posts

QSK60 CM2358 Engine Camshaft Speed/Position Sensor Data Erratic Incorrect

This illustration show you guide on how to repair Cummings QSK60 CM2358 engine camshaft speed/position…

1 week ago

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

1 week ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

2 weeks ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

2 weeks ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

2 weeks ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

2 weeks ago