Fendt 1000 S4 Tractor 1001 Crossgate Lever Calibration Guide

Here is the instruction show you guide on how to calibrate 1001 crossgate for Fendt 1000 S4 tractor.

Crossgate lever

A Raise

B Lower/press

C Floating position

 

Related Contents:

FENDT Fendias 2024.v2 with USB Dongle

AGCO 2×4 CANUSB

 

Procedures:

Important: Refer to Service Information 18/2012.

1 Apply the hand brake

2 Switch on ignition.

3 Press to confirm any existing errors displayed in the instrument cluster

4 Press to display the first main menu level

5 Press until symbol A flashes

6 Press to display the second main menu level

7 Press until symbol A flashes

8 Press to display the auxiliary spool valve menu level

9 Press until symbol A flashes

10 Press to be able to enter the calibration code

11 Press and enter code 1001

12 Confirm with

13 Release crossgate lever → it centers automatically

14  Confirm with

15 Push and hold the crossgate lever fully right (with the spring)

16  Confirm with

17  Push and hold the crossgate lever fully left (with the spring)

18  Confirm with

19  Push and hold the crossgate lever fully forwards (with the spring)

20  Confirm with

21 Push and hold the crossgate lever fully backwards (with the spring)

22  Confirm with

23  Push and hold the crossgate lever fully right (with the spring)

24  In this position, push and hold the crossgate lever fully forwards (with the spring)

25  Confirm with

26  Push and hold the crossgate lever fully right (with the spring)

27  In this position, push and hold the crossgate lever fully backwards (with the spring)

28  Confirm with

29  Push and hold the crossgate lever fully left (with the spring)

30  In this position, push and hold the crossgate lever fully backwards (with the spring)

31  Confirm with

32  Push and hold the crossgate lever fully left (with the spring)

33  In this position, push and hold the crossgate lever fully forwards (with the spring)

34  Confirm with

35  Push and hold the crossgate lever fully right (not with the spring)

36 Confirm with

37  Push and hold the crossgate lever fully left (not with the spring)

38  Confirm with

39  Push and hold the crossgate lever fully forwards (not with the spring)

40 Confirm with

41  Push and hold the crossgate lever fully backwards (not with the spring)

42  Confirm with

43  If calibration is error-free, OK appears and the calibration values are stored

Note:

The values are not applied until after a key reset.

Wait at least 60 seconds before switching the ignition ON.

44  If incorrect values are detected or the conditions were not met, ERROR appears

1001

Calibration code

FXX

Fault code

auto

Recent Posts

How to Solve PowerCommand PCC2300 Fault Code 143 Low Oil Rifle Pressure

This instruction show you guide on how to to solve PowerCommand PCC2300 trouble code 143…

6 days ago

How to Solve HINO J05E Engine P007B Intake Air Temperature Sensor Error

Here is the instruction show you guide on how to solve HINO J05E engine P007B…

1 week ago

AGCO EEM5 Stage V CORE 75-80 Supply Module

The supply module (SM) is a part of the vehicle SCR system. The SM is…

2 weeks ago

Yale G807 Brake System Air Bleed Guide

Yale G807 Brake System Air Bleed Guide   Related Contents: 2023 Yale PC Service Tool…

2 weeks ago

Bobcat G2 Stage V Engine P000F Common rail pressure Open Error Solution

This instruction show you guide on how to solve Bobcat G2 Stage V engine P000F…

3 weeks ago

How to Solve CASE 7120 IH 20 Series Axial-Flow Combine Creep Problem

Here is the instruction show you guide on how to solve CASE 7120 IH 20…

3 weeks ago