This instruction show you guide on how to solve Fendt MT1149 tractor measured DEF tank temperature sensor signal is above or below normal operating range.
Preparations:
Code SA 00 SPN 3031 FMI 03
Measured DEF tank temperature sensor signal is above normal operating range.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code occurs again during the next driving cycle, check the following.
Check the DEF tank temperature sensor harness. Make sure the connections are good and the contacts are clean.
Replace the DEF tank temperature sensor. If the system is correct and the fault code is not active, the original sensor is bad.
Code SA 00 SPN 3031 FMI 04
Measured DEF tank temperature sensor signal is below normal operating range.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code occurs again during the next driving cycle, check the following.
Check the DEF tank temperature sensor harness. Make sure the connections are good and the contacts are clean.
Replace the DEF tank temperature sensor. If the system is correct and the fault code is not active, the original sensor is bad.
If you want more repair cases for Fendt tractor,please refer to Fendt Tractor Trouble Repair
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…
This is instruction show you guide on how to adjust cruise control release linkage for…
This instruction show you guide on how to use AGCO EDT diagnostic software to perform…