Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF tank temperature does not change during the heating cycle.
Preparations:
Code SA 00 SPN 3031 FMI 10
The DEF tank temperature does not change during the heating cycle.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code shows again during the next driving cycle, check the following.
Check the coolant supply of the tank heating element.
Install a new DEF tank heating valve to see if the original is bad.
Check the DEF tank temperature sensor harness. Make sure the connections are good and the contacts are clean.
Replace the DEF tank temperature sensor. If the system is correct and the fault code is not active, the original sensor is bad.
If you want more repair cases for Fendt tractor,please refer to Fendt Tractor Trouble Repair
This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…
Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…
Here is the instruction show you guide on how to set play between timing pinion…
Perkins 1106D Generation Injector Data Incorrect Test Guide Preparations: Perkins EST 2024A & 2023A…
This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…
Here show guide on how to check high pressure relief valve pressure for Kubota L4701…