FUSO Truck Startup/Control Unit Programming after Replacement

Fuso truck startup/control unit replacement initialization need to be done before writing the old ECU’s software and coding parameters downloaded from the FRN into the new ECU to make the contents of both ECUs identical.

This task is applied to the following ECUs to which software is not written.

MCM: Engine ECU (heavy-duty)

ACM: SCR ECU (heavy-duty, medium-duty)

EEC: Engine ECU (light-duty)

TCM: DUONIC Control unit

 

Caution

Please perform “coding”, when you replace ECUs other than the above.

Although the menu of some ECUs has “Control unit replacement”, since it is preparing as backup

when unexpected fault occurs, please do not perform, when there are no directions.

 

Related Contents:

Benz Xentry OpenShell.XDOS 2023 Free Download

How to Install Benz Xentry 06.2023 Diagnostic Software

 

Procedures:

(1) Select “Control unit replacement”.

(2) Click “Continue”.

(3) Click “Continue”.

(4) Enter the inquiry number and password obtained from the FRN.

(Be sure to enter the alphabet part in the inquiry number in capital letters.)

(5) Click “Continue”.

Check that the ECU software version and object number have been transferred from the ECU before replacement. When normally completed, proceed to tasks such as initial setup as required.

Be sure to perform initial setup of the DUONIC® by referring to the shop manual.

auto

Recent Posts

Jungheinrich Junior AME13 Spring-Loaded Brake Electrical Connection Removal Guide

It is necessary step to remove electrical connection cable before you do disassemble or some…

2 days ago

How to Use Nexiq eTechnician Function Test?

Nexiq eTechnician provides a number of special tests to assist you with your vehicle diagnostic…

3 days ago

JCB JS140 Excavator P0523-68 Engine Oil Pressure Low Solution

Here car-auto-repair.com show you guide on how to repair JCB JS140 excavator P0523-68 trouble code…

4 days ago

Volvo Version 3 and 4 Truck Oil Pressure Test by Volvo Techtool

Here is the instruction show you guide on how to use Volvo TECHTOOL and VOCOM adapter to…

6 days ago

How to Solve Allison 3000 & 4000 Gen5 P071A Neutral at Stop Input Failed ON

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 transmission…

1 week ago

Mack and Volvo EPA13 GHG17 Engine NOx Conversion Monitor Test

This instruction show you guide on how to use JPRO TO perform Mack and Volvo…

1 week ago