GDS2200 CE Operating System Update Procedure

Double click GDS2200_Installer.exe to start the installation. If an OS update is needed, you will need approximately 30 minutes. Choose Yes when you see the following prompt:

Follow the on-screen instructions. This is Step 1. (Subsequent updates may not need to perform this step; if this is the case, then the process will begin at step 2.)

NOTE: These instructions are available in the appendix at the end of this document.

 

While step 1 of the operating system update is in progress, the bar graph shows the current status. This Bar graph will complete two times; when this has completed for the second time and the progress bar is no longer moving the HDS tablet tester requires

REBOOTING! Reboot the tablet tester.

This is step 2.

NOTE: These instructions are available in the appendix at the end of this document.

While step 2 of the Operating System update is in progress, the bar graph shows the current status. This bar graph will complete two times.

After the bar graph has complete two times the Teradyne Diagnostic Solutions screen will appear for approximately 4 minutes. Do not touch the Tablet screen or undock the Tablet during this screen.

This is Step 3.

The tester will reboot automatically. It may take up to 2 minutes for the reboot to complete.

When the tester has rebooted, the following screen will be displayed.

After approximately 2 minutes, the tester will be rebooted again. This reboot may take up to a further 2 minutes to complete, during which time the following screen will be displayed.

Once the Operating System has been successfully installed, click Finish.

The HDS software will automatically load. Follow all screen prompts carefully.

auto

Recent Posts

How to Solve JCB SPN 102, FMI 1 Boost Pressure Sensor: Pressure Below Normal

Here is the instruction show you guide on how to JCB machine SPN 102,FMI 1…

20 hours ago

How to Install Preconcave for CLAAS Lexion 480 Combine

This instruction show you guide on how to install preconcave for CLAAS Lexion 480 combine…

3 days ago

Deutz EMR3 Trouble Code 78/ 190 Speed Sensor Signals Out of Phase

This instruction show you guide on how to solve Deutz EMR3 trouble code 78/ 190 EngMOfsCaSCrS Speed…

7 days ago

How to Release Park Brake Manually for CASE IH 20 Series Combine

This instruction show you guide on how to release park brake manually for CASE IH…

1 week ago

How to Replace High Pressure Limit Valve for Fendt 900 Vario COM III?

Here is the instruction show you guide on how to replace high pressure limit valve…

2 weeks ago

How to Select JCB Machine AJ45E Machine Software

There are three software options for Machine Software on AJ45E&EH machines.   Related Contents: 2025 JCB…

2 weeks ago