This illustration show you guide on how to perform air bleeding from hydraulic oil tank for Hitachi EX5600-7B hydraulic excavator.
Related Contents:
Hitachi MPDr v2.56 v2.25 Diagnostic Software Free Download
2016 HITACHI Parts Manager Pro 6.5.5 Free Download
2019 Hitachi Workshop Service Manual PDF Download
Escaping fluid under pressure may penetrate the skin and eyes, and cause serious injury. Release pressure before disconnecting the hydraulic pipings or removing other equipment.
Hot hydraulic oil just after operation may spout out and cause severe burns. Allow oil to cool before starting any work.
If cap (1) of hydraulic oil tank is turned quickly, there is the danger that internal pressure may cause the cap (1) to fly off. Allow internal pressure to escape before removing cap (1).
Preparation
1.Set the machine position for inspection and maintenance. Stop the engine.
2.Use hex wrench (a) and loosen the lock of one of the hydraulic oil tank caps (1) (2 used).
3.Turn cap (1) 30 degrees counterclockwise. Bleed the air from inside the hydraulic oil tank.
NOTE:
1.When operating the vacuum pump to apply negative pressure to the hydraulic oil tank, close cock (5) on the hydraulic oil tank air release valve.
After work is completed, open cock (5).
2.Remove socket bolt (2) from cap (1) on one side,then remove air breather cap (1). Remove filter (3).
Wrap tape approximately once around in order to block hole (b) on bayonet assembly (4), Install filter (3) and air breather cap (1) in their original positions.
3.Remove the other cap (1). Connect vacuum pump(f). Start vacuum pump (f) and apply negative pressure to the hydraulic oil tank. Operate vacuum pump (f) continuously while working.
4.After work is completed, remove the tape from bayonet assembly (4).
More repair case for Hitachi mahcine,please refer to:Hitachi Machine Repair
This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…
Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…
Here is the instruction show you guide on how to set play between timing pinion…
Perkins 1106D Generation Injector Data Incorrect Test Guide Preparations: Perkins EST 2024A & 2023A…
This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…
Here show guide on how to check high pressure relief valve pressure for Kubota L4701…