This instruction show you guide on how to perform No load max differential pressure measurement for HITACHI ZX-5 excavator.
What You Need?
Hitachi AllinOne MPDr v3.32 v2.25 2021 Diagnostic Software Free Download
Measurement of No Load Max differential pressure can be done.
When the fault code of ECM muffler filter PM Over-Restriction is displayed, check the muffler filter condition by measuring
No Load Max differential pressure.
Check the muffler filter condition.
Refer to the Technical Manual (Troubleshooting).
1. Click the [[F] No Load Max Differential Pressure Measurement] button.
2.Measure the differential pressure by following the procedure displayed on the monitor screen.
Step 1: Warm the engine.
Raise the boom and relief at arm crowd end. Bring the Coolant Temperature to
70 deg.C or more,the MF Filter Inlet Temperature to 200 deg.C or more.
Step 2:
Turn the engine control dial to LOW.
Raise the Pilot Control Shut-Off Lever.
Turn OFF Auto Idle.
Turn OFF Auto Shut-Down.
Step 3:
Wait until the MF Filter Inlet Temperature is 140 deg.C or less.
Step 4:
Bring the Actual Engine Speed to 1700min-1.Wait until the MF Filter Inlet
Temperature is 150 deg.C or more
Completion:
The measurement task is now complete.
Return Auto Idle. Auto Shut-Down and Power Mode switching settings to the original. This completes the task.
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…
This is instruction show you guide on how to adjust cruise control release linkage for…
This instruction show you guide on how to use AGCO EDT diagnostic software to perform…