Categories: Excavator Repair

How to Adjust Valve Clearance for Komatsu Excavator PC130

This is a guide focus on how to adjust valve clearance for Komatsu excavator PC130.All workshop manual and part catalogue you can refer to:Komatsu CSS Full Set 2018 2014 Parts Viwer Free Download

 

Note:Stop the machine on a level ground and lower the work equipment to the ground.

Adjust the valve clearance under the following condition.
Engine coolant temperature: Normal temperature

 

Procedures:

1.Open the engine hood and remove maintenance step (1) and air supply hose (2) on the engine

2.Remove cylinder head cover (4).

3.Remove plate (5) on the starting motor and insert gear B1.

4.Remove compression top dead center TDC check plug (6) from the flywheel housing.
Rotate the crankshaft forward with gear B1 and set it so that you can see the white mark of the flywheel.

When the No. 1 cylinder is at the compression top dead center, the rocker arm of the No. 1 cylinder can be moved by the valve clearance with the hand. If the rocker arm cannot be moved, the No. 1 cylinder is not at the compression top dead center. In this case, rotate the crankshaft one more turn.

auto

Recent Posts

Hitachi EX5600-7B Folding Stairway and Surrounding Parts Removal Guide

This instruction show you guide on how to remove folding stairway and surrounding part for…

1 hour ago

Jungheinrich Junior AME13 Spring-Loaded Brake Electrical Connection Removal Guide

It is necessary step to remove electrical connection cable before you do disassemble or some…

2 days ago

How to Use Nexiq eTechnician Function Test?

Nexiq eTechnician provides a number of special tests to assist you with your vehicle diagnostic…

4 days ago

JCB JS140 Excavator P0523-68 Engine Oil Pressure Low Solution

Here car-auto-repair.com show you guide on how to repair JCB JS140 excavator P0523-68 trouble code…

5 days ago

Volvo Version 3 and 4 Truck Oil Pressure Test by Volvo Techtool

Here is the instruction show you guide on how to use Volvo TECHTOOL and VOCOM adapter to…

6 days ago

How to Solve Allison 3000 & 4000 Gen5 P071A Neutral at Stop Input Failed ON

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 transmission…

1 week ago