How to Change Contant Speed for Deutz Engine by SerDia2010

This instruction show you guide on how to change constant speed for Deutz engine with EDC17 by SerDia2010 diagnostic software. To use this function, the engine has to be in fixspeed mode or
the setting allows to activate the fixspeed mode.

 

Related Contents:

Deutz Diagnostic Kit DECOM for Deutz Engine

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Serpic EPC Parts Catalogue 2014 2012 Free Download

 

Screen change constant speed
The actual setting for the fixspeed values are shown on the left upper part of the screen.
The setting of the switch is marked, too
Additionally the actual engine speed and the speed setpoint is shown as value and tachometer
on the right side inclusive hysteresis to have a qualitative feedback.

 

Button “read from ECU”:

Button “write values to ECU”:

Values shown on the screen for fixspeed 2 (first intermediate speed)
and fixspeed 3 (2. intermediate speed) are flashed to the ECU.
If the engine is still running while activation of this procedure, SerDia will ask to stop
engine automatically

Textbox “Constant Speed 2″,”Constant Speed 3”:

Changes in these textboxes have to be confirmed with ENTER.
After confirmation the new value will get active, if switched on (see marking point at fixspeed).
It is not possible to install a speed below fixspeed one or above fixspeed four.
The fixspeeds 1 and 4 are not changeable in this screen (see hints above).

For more repair case of Deutz engine,please refer to:Deutz Engine Repair

auto

Recent Posts

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

20 hours ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

1 day ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

3 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

4 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

5 days ago

How to Perform Relative Cylinder Compression Test for Detroit GHG17 Engine

This illustration show you how to use Detroit Diesel Diagnostic Link diagnostic software to do…

6 days ago