This instruction will show you how to perform Key Programming function via Zenith diagnostic scan tool on 2012 Chevrolet Orlando’s Immobilizer system.

 

Procedures:

Connect Zenith with vehicle by OBD, running Zenith.

Select “ DIAGNOSIS”

Select “GM”–>”Automatic selection”

Confirmed the model and select “OK”

Proceed “System Search”, click “OK”

Select correct engine model, click “OK”

Scroll down the menu and find “Immobilizer”

Select “Special Function”–>”Key programming”

Read the description carefully, then click “OK”

Have the spare key(s) ready for programming.

When you’re click Ok, all previous learned keys will be erased/deleted from the Immobilizer module’s memory.

Turn the IG ot OFF position

Turn the IG to ON position

Wait for a moment, follow the screen turn the IG to OFF position, then ON position again

Then the process of deleting keys will take 600 seconds

All keys are now deleted, click “OK”

Turn the IG OFF and remove the key

Open and close the driver’s door, click “OK”

Wait for 45 seconds

Insert a new key and turn IG to ON position

Inserted key is learned successfully

Repeat the same procedure for second key learning, if you don’t have it, click “No”

Follow the screen description. Turn the ignition to Off and remove the key again.

Open and close the door, click “OK”, then wait for 45 seconds

Insert the key and turn the ignition to ON position.

Key programming function is now completed.

 

More key program cases, please refer to Chevrolet Key Programming.

 

 

Kevin

Recent Posts

Volvo and Mack EPA 10 Engine Hydrocarbon Dosing Control Valve Test by JPRO

This instruction show you guide on how to perform hydrocarbon dosing control valve test for…

3 days ago

Fendt Tractor SPN 100 FMI 31 Oil Pressure Sensor Defect Solution

This instruction show you guide on how to solve Fendt tractor SPN 100 FMI 31…

4 days ago

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure   Related Contents: 2024.06 Detroit Diesel…

6 days ago

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.…

1 week ago

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout   Vehicles: Monza, Kadett and…

1 week ago

How to Remove Oil Pressure Regulation Valve for CLAAS AXION 950

This illustration show you guide on how to remove oil pressure regulation valve for CLAAS…

1 week ago