How to Execute Nox Sensor Change for Deutz Engine

The service case “Nox sensor change” has to be executed after each Nox sensor change. It is than insured,that the right Nox sensor with the right dataset are installed on the system. The new generation of Nox sensor (Gen 2.5) are introduced.

 

Related Contents:

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Diagnostic Kit DECOM for Deutz Engine

 

 

Especially for the exchange of NOx sensors of this service Case was introduced in Serdia.
In the next image the reason why new generation of NOx sensors was introduced at Deutz.
After selecting and executing the Service-Case NOx sensor replacement the following message appears on the screen, which can be confirmed with the green arrow.

Deutz Communicator

If a test condition is not met, the process will be aborted with this message.

In the next step Serdia will prompt you to select the old part number from the removed NOx sensor.

Since there is only a limited selection of published Deutz NOx sensors, equivalent numbers can be selected in a drop-down window.

After the routine of the Service-Cases with all necessary data for a successful NOx sensor exchange.

This function is available at a higher Competence Class than Level 3.

More topic for Deutz,please refer to Deutz Trouble Repair

auto

Recent Posts

Jungheinrich Junior AME13 Spring-Loaded Brake Electrical Connection Removal Guide

It is necessary step to remove electrical connection cable before you do disassemble or some…

1 day ago

How to Use Nexiq eTechnician Function Test?

Nexiq eTechnician provides a number of special tests to assist you with your vehicle diagnostic…

3 days ago

JCB JS140 Excavator P0523-68 Engine Oil Pressure Low Solution

Here car-auto-repair.com show you guide on how to repair JCB JS140 excavator P0523-68 trouble code…

4 days ago

Volvo Version 3 and 4 Truck Oil Pressure Test by Volvo Techtool

Here is the instruction show you guide on how to use Volvo TECHTOOL and VOCOM adapter to…

6 days ago

How to Solve Allison 3000 & 4000 Gen5 P071A Neutral at Stop Input Failed ON

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 transmission…

1 week ago

Mack and Volvo EPA13 GHG17 Engine NOx Conversion Monitor Test

This instruction show you guide on how to use JPRO TO perform Mack and Volvo…

1 week ago