How to Install DiagBox v8.01 Software

This article show the guide on how to install DiagBox v8.01 diagnostic software.This method provided by the cartechnology remember simple,big thanks to him selfless work.

psa_diagbox_1

 

Note: If using a Virtual Machine, ensure Virtualization is enabled in the physical laptop BIOS.

 

Preparation for Installing DiagBox 8.01 on Notebooks and VMWare Workstation
– Starting with any (32 bit) Windows (preferably XP or 7), install .NET 3.51 and Windows drivers or VMWare Tools (if on VMWare Workstation or Player).

Preparation for Installing DiagBox 8.01 on VirtualBox
– Settings –> System: Motherboard, ensure APIC is OFF, use one processor and enable Virtualization. Allocate enough memory for VM.
– Having installed 32 bit Windows + VirtualBox Guest Additions + .NET 3.51, use the Powershell Command “Get-WMIObject win32_BIOS” or the “DMIdecode” tool to obtain BIOS information (not essential).
– Close VirtualBox and start an administrator’s CMD, navigate to “C:\Program Files\Oracle\VirtualBox\” and execute the following command (Replacing “Your VM” with your Virtual Machine’s name, and System Serial with your hardware’s or any code or text such as “CDN29326BH”):
C:\Program Files\Oracle\VirtualBox>VBoxManage setextradata “Your VM” “VBoxInternal/Devices/pcbios/0/Config/DmiSystemSerial” “System Serial”

Installing DiagBox 8.01
1- Install DiagBox 7.01 and restart DiagBox to run update 7.02. Install update 7.xx-7.57 (this will create “C:\AWRoot\dtwr\cfg\Config.sys”).
2- Install “VC++ 2008 Redistributable Package”, a copy will be available in “C:\teleassistance\visualC\vcredist_x86.exe” after installing DiagBox.
3- Restart the computer and use “Kill_DiagBox_Tasks.bat” to stop related processes and rename “C:\AWRoot” to “C:\AWRoot7”
4- Run DiagBox 8.01 installation (it will uninstall v7.xx first) until it requests Activation. Close it (X) and run the tool “AWRoot_v7_Conf+Ativation_v8.exe” it will copy configuration from “C:\AWRoot7\..” and inject the necessary files.
5- Run DiagBox again, it should continue the installation successfully.

Done !,

Restart DiagBox 8.01 as Administrator to confirm all is well (don’t be concerned about the reported version and do not start Lexia or PP2000 yet). If you face an issue, run the activation tool again and/or review “Versions” below.

If DiagBox runs fine, ensure you keep a backup copy of the file “C:\AWRoot\bin\fi\APPDIAG.SYS” in a safe location.

Installing Updates
1- Download and install “DiagBox_updt_802.ISO” update.
2- Download and install subsequent v8.xx updates or Maitresox updates (from 7.66+).

 

Tool you need:

DiagBox Full v8.01 ISO:

https://mega.nz/#!V092FQrJ!5Em-RhtO8XfdziSVLqwpqKKfPxV-b6n8XCHdhAQEgBI

 

AWRoot_v7_Conf+Ativation_v8.exe            No password

https://mega.nz/#!4lkUUI7C!2Gqp4ma0frNc5cSdf12L86O3wIvJD3cLkZSq5Y5klOY

 

DiagBox updates working with DiagBox V8.01 based on v7.xx profile, Extraction Password: Simple

 

DiagBox_updt_802_Simple.exe

https://mega.nz/#!Zx8U3SIb!19OlA1UmOqQzqMdYb9KVf95h8QiIpFDwmg4hVIeSToY

 

DiagBox_updt_803-810_Simple.exe

https://mega.nz/#!skMmAYgB!ygpcYNuOeTU8z0K7aKKyHM7_Qe4xg0EMfSZfHBU5T4s

 

DiagBox_updt_811-814_Simple.exe

https://mega.nz/#!AtMQDB4L!YXytKXPhIyxeXu_j9PXDqTXw5ppqnCD2ud5qXD_W6oU

 

DiagBox_updt_815-817_Simple.exe

https://mega.nz/#!hhVUwSaD!qlseKqwftJF4eVRLG-h5bk3pJ3V2jcRLxKEN_MiuuuA

 

For those who wish to stay with (ISO 639-1) standard:

 

DiagBox_updt_803-808_Simple.exe  (7.72)   Password: Simple #808

https://mega.nz/#!Q0FEiY7K!xkU5PlkGOQv0sg9I1KHxw4yIgU0XwHguJaWSbz79xVU

 

And those who wish to continue further:

DiagBox_updt_810_Simple.exe      (7.74)   No Password

https://mega.nz/#!IsFQAZia!y5S_rGcjsY6fIjrL9VMGmFPSVYVwqBSzLhr8dJ9e8LY

 

Cache Contents Restorer                   No password

https://mega.nz/#!M113GKgC!DqCt18QSX8Mz7onRoClrYXXtBo3JT1qPF0jgSUJEAEM

 

Kill_DiagBox_Tasks

https://mega.nz/#!VVM1ka7Q!rA7X2VisNNs4DM7_bolaZGm4Dv_3Mqmgg_Dd1fmX6fc

 

Versions
DiagBox will run and display the (8.xx or 7.xx) version number listed in “AWRoot\bin\fi\version.ini” file. However, Lexia or PP2000 will fail to operate with “version.ini” set to “08.xx” and “APPDIAG.SYS” will be corrupted and will need to be restored before DiagBox will work again.
So, for DiagBox, Lexia and PP2000 to operate, set the version to “7.xx” or “7.xxx” (07.81 or 07.817 can be set to indicate the true DiagBox 8 version).
[APPLICATION]
version=07.817

It is possible to operate Lexia/PP2000 (after starting DiagBox with 8.xx) by starting DiagBox while having “version.ini” listing the 8.xx only (or first), then changing it to 7.xx or commenting the line “version=08.xx” and saving BEFORE starting LEXIA or PP2000 as shown below.
[APPLICATION]
;version=08.01
version=07.65

Updates
– DiagBox v7 and v8 install and run on all x86 (32bit) Windows including 10 TH1, TH2, RS1 and RS2.
– Entering a System Serial for the Virtual Machine (as described above) resolves the “psaAagent.exe” and the missing tabs issue on VirtualBox.
– If you get “Error 2” after restarting DiagBox, try commenting “version=8.xx” in “version.ini” before restarting DiagBox again.

P.S. DiagBox has been running on Firmware 4.3.4 since 7.66/8.02.

Someone put the full installation process on the net, just edit “version.ini” as described above.

Visited 1 times, 1 visit(s) today