In cases where an engine ECU is replaced, or a calibration is corrupted the following process should be used to load the correct engine calibration onto an ECU.

 

Related Contents:

2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

 

Steps:

1.Make the machine safe. Refer to the procedure in the Operators Manual.

2.Load the DECU software onto the USB storage device.

Open the ServiceMaster and select the correct shortcut fir your machine model

The ServiceMaster will take you to the correct file location for that machine model

Plug the USB storage device into the USB port of your laptop

When the USB storage device is connected. copy the encrypted file

3.Remove the cap screws that secure the DECU rear cover

4.Remove the rear cover to expose the USB port

5.Locate the USB port and insert the USB storage device that contains the software encrypted file

6.Turn the ignition to ON position

7.If the software is not correctly installed on the USB storage device or is corrupt or does not contain the software, the DECU screen will display the below symbol

8.If the software is correctly installed on the USB storage device, the machine will automatically detect the software and will start to download

9.The DECU screen will display the USB symbol (shown below) on the screen and will flash ON and OFF every second whole the software is downloaded

10.When the software loading is complete, the DECU screen will display the below symbol

11Remove the USB storage device

12.Install the rear cover onto the DECU

13.The procedure is now complete

auto

Recent Posts

Volvo and Mack EPA 10 Engine Hydrocarbon Dosing Control Valve Test by JPRO

This instruction show you guide on how to perform hydrocarbon dosing control valve test for…

2 days ago

Fendt Tractor SPN 100 FMI 31 Oil Pressure Sensor Defect Solution

This instruction show you guide on how to solve Fendt tractor SPN 100 FMI 31…

4 days ago

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure   Related Contents: 2024.06 Detroit Diesel…

6 days ago

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.…

1 week ago

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout   Vehicles: Monza, Kadett and…

1 week ago

How to Remove Oil Pressure Regulation Valve for CLAAS AXION 950

This illustration show you guide on how to remove oil pressure regulation valve for CLAAS…

1 week ago