Here is the instruction show you guide on how to remove and install thermostat for CLAAS Lexion 480 machine.
Related Contents:
CLAAS CDS 7.5 Diagnostic Software 2021 2020 Free Download
CLAAS USB Interface Diagnostic Adapter Package
STEPS:
Removing the thermostat
Fold up the cab roof.
Unscrew the cover (A) from the cab top.
Carefully pull off the sealing plate (5).
Remove sealing compound (B).
Carefully pull capillary tube (C) out of the evaporator (23).
Remove the cover (D).
Disconnect cable plug from the temperature switch (9).
Loosen clamp (E).
Pull off rotary control (10), unscrew temperature switch (9) from cover (D) and carefully pull out capillary tube (C).
Installing the thermostat
1 Guide capillary tube (C) of the temperature switch (9) through the cab covering, bend a 90° angle approx. 80 mm from the end and carefully push it into the evaporator (23) at (X and Y).
(X) = 60 mm
(Y) = 30 mm
2 Fasten capillary tube (C) using clamp (E).
3 Screw down temperature switch (9) to cover (D) and fit rotary control (10).
4 Connect cable plug to temperature switch (9).
5 Isolate temperature switch (9) using sealing compound.
6 Install cover (D).
7 Seal pipe leadthrough with sealing compound (B).
8 Glue on sealing plate (5).
9 Screw down the cover (A) to the cab top.
More repair case for CLAAS,please refer to CLAAS Trouble Repair
This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…
Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…
Here is the instruction show you guide on how to set play between timing pinion…
Perkins 1106D Generation Injector Data Incorrect Test Guide Preparations: Perkins EST 2024A & 2023A…
This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…
Here show guide on how to check high pressure relief valve pressure for Kubota L4701…