Heavy Equipment Repair

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for HITACHI EX5600-7B excavator.

 

 

Related Contents:

Hitachi Dr.ZX diagnostic Tool

Hitachi AllinOne MPDr v3.32 v2.25 2021 Diagnostic Software Free Download

Hitachi Excavator ZX-5A ZX-5B ZX-5G Workshop Service Manuals PDF

 

 

Procedures:

1 Remove the hoses under center joint (1).

2 Remove bolts (2) (4 used) and washers (3) (4 used).

Remove cover (1).

 

3 Remove bolts (1) (6 used) and washers (2) (6 used).

Remove cover (3).

j : 22 mm

4 Remove bolts, washers (4) (4 used) and clamps (5) (2 used).

j : 17 mm

5 Disconnect the both ends of pipes (6) (24 used).

j : 17 mm

 

 

CAUTION: Upperstructure (1) weight: 50100 kg

(110500 lb)

IMPORTANT: Install a soft rubber onto the wire rope contacting surface in order not to damage the main frame.

 

6 Install shackles (2 used) to lifting holes (a) (2 places).

Attach nylon slings onto the shackles (2 used).

Attach wire ropes onto counterweight mounting parts (b) (2 places). Hoist and hold upperstructure

(1) by using nylon slings and wire ropes.

 

7 Put the matching marks on upperstructure (1) and undercarriage (2). Remove bolts (3) (62 used) and washers (4) (62 used). Remove upperstructure (1) from undercarriage (2). Place upperstructure (1) onto wooden blocks.

 

More repair case for Hitachi,please refer to Hitachi excavator trouble repair

auto

Recent Posts

Doosan Stage V Machine U0632 CAN-Receive-Frame Timeout Error Solution

This instruction show you guide on how to solve Doosan Stage V machine U0632 timeout…

21 hours ago

CASE IH 20 Series Combine Park Brake Piston Travel and Adjustment

This instruction show you guide on how travel and adjust park brake piston for CASE…

3 days ago

How to Replace Purge Valve for Fendt 900 Vario COM III Tractor?

Here is the instruction show you guide on how to replace purge valve for Fendit…

6 days ago

How to Solve JCB SPN 102, FMI 1 Boost Pressure Sensor: Pressure Below Normal

Here is the instruction show you guide on how to JCB machine SPN 102,FMI 1…

1 week ago

How to Install Preconcave for CLAAS Lexion 480 Combine

This instruction show you guide on how to install preconcave for CLAAS Lexion 480 combine…

2 weeks ago

Deutz EMR3 Trouble Code 78/ 190 Speed Sensor Signals Out of Phase

This instruction show you guide on how to solve Deutz EMR3 trouble code 78/ 190 EngMOfsCaSCrS Speed…

2 weeks ago