Troubleshooting intermittent faults is very difficult. Re-creating the fault is going to be the most beneficial method of narrowing down the possible problems. If this is not possible, there are methods of identifying the problem areas. Below are a few:
Possible Causes:
1.Corroded connections
2.Broken wires (visible or inside the insulation)
3.Poor system grounds
4.Bad battery cables
5.Pushed back pins
6.Female pins damaged or expanded
7.Worn wire harness
8.Poor wire repairs done at a previous time
More repair topic for Bobcat,please refer to:Bobcat Excavator Repair
Troubleshooting these problems should involve the following steps:
1.If possible, find out all necessary details as to when the error occurs
a.when it happens (at start-up or after operation)
b.when it doesn’t
c.applications
d.attachments used
e.weather conditions
f.options or kits installed
g.software version of the main Bobcat controller
h.software version of all other controllers
2.With the system powered up to a point where the error is expected, shake the wire harness along its entire circuit, paying attention to the point where the error re-occurs, if it does.
3.Inspect ALL connectors within the circuits of concern to verify that they are: a.Free of corrosion or moisture b.All pins are fully seated in the connector c.The female terminals are not expanded to cause intermittent connection d.Connectors are fully mated together
4.Visually inspect the wire harness(es) that contains the circuitry in question, looking for any points of wear or rub-through (especially the underside when the harness is laying over another component)
5.Look at the condition of a controller in the system. Check for damaged connectors or separation of black potting material from the edge of the controller case which may allow moisture ingression.
Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…
Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…
Here is the illustration show you guide on how to solve Perkins 1106D electric power…
Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…
This instruction show you guide on how to perform No load max differential pressure measurement…
Here is the instruction show you guide on how to solve Doosan machine P02EB over…