How to Solve Fendt MT1149 Tractor DEF Tank Level Sensor Voltage Error

Here is an illustration show you guide on how to solve Fendt MT1149 tractor DEF tank level sensor voltage is above and below normal operating range.

 

 

Preparations:

AGCO EDT 2024

AGCO 2×4 CANUSB

 

 

Measured DEF tank level sensor voltage is above normal operating range

Diagnosis and solution

Clear the error log.

Restart the engine module.

If the fault code occurs again during the next driving cycle, check the following.

Make sure the DEF tank is full.

Check the DEF tank level sensor harness. Make sure the connections are good and the contacts are clean.

Replace the DEF tank level sensor. If the system is correct and the fault code is not active, the original sensor is bad.

How to Solve Fendt MT1149 Tractor DEF Tank Level Sensor Voltage Error (1) How to Solve Fendt MT1149 Tractor DEF Tank Level Sensor Voltage Error (2)

Measured DEF tank level sensor voltage is below normal operating range

Diagnosis and solution

Clear the error log.

Restart the engine module.

If the fault code shows again during the next driving cycle, check the following.

Check the DEF tank level sensor harness. Make sure the connections are good and the contacts are clean.

Replace the DEF tank level sensor. If the system is correct and the fault code is not active, the original sensor is bad.

 

If you want more repair cases for Fendt tractor,please refer to Fendt Tractor Trouble Repair

Visited 1 times, 1 visit(s) today