Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR system error. Emptying not completed at previous shutdown.
Preparations:
Code SA 00 SPN 4332 FMI 31
SCR system error. Emptying not completed at previous shutdown.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code shows again during the next driving cycle, check the following.
Check the machine main switch operation. If the main switch is manual, do not switch off until the DEF system is empty.
Replace the DEF supply module. If the system is correct and the fault code is not active, the original DEF supply module is bad.