Here is the illustration show you guide on how to solve Perkins 1106D electric power generation E398 low fuel rail pressure error.

 

Preparations:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

Perkins Communication Adapter 3

 

 

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects a fault with low fuel rail pressure. The ECM detects the following faults:

  • The ECM determines that the expected fuel rail pressure is lower than the pressure that is
    requested by the electronic control system.
    • Diagnostic code 262-3 5 Volt Sensor DC Power Supply voltage above normal is not active.
    • Diagnostic code 262-4 5 Volt Sensor DC Power Supply voltage below normal is not active.
    • Diagnostic code 1797-3 Fuel Rail Pressure Sensor voltage above normal is not active.
    • Diagnostic code 1797-4 Fuel Rail Pressure Sensor voltage below normal is not active.
    • No diagnostic codes are active for the fuel rail pump.
    • No diagnostic codes are active for the fuel injectors.

System Response:
The warning lamp will be illuminated and the diagnostic lamp will flash the event code.
The event code will be logged.

Possible Performance Effect:

E398-2
The derate lamp will be illuminated.
The engine will be derated until the keyswitch is turned to OFF and then turned to ON.

Troubleshooting:
Low fuel pressure may be caused by the following faults:
• A fault in the fuel return system
• A fault in the fuel pressure control
• A leak in the high pressure fuel system
• A failed relief valve, the fuel pump or an electronic unit injector

 

The event code does not represent a fault in the electronic system. Refer to Systems Operation,
Testing and Adjusting, “Fuel System – Inspect”.

Results:
• OK – STOP.

 