Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.
There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.
Related Contents:
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnostic Kit DECOM for Deutz Engine
Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:
2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).
In the lower window following table is shown:
X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.
Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.
Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.
Notice:This function is available at Competence Class Level 2.
This instruction show you guide on how to solve spool brake solenoid open circuit for…
This instruction show you guide on how to remove and install crankshaft rear seal for…
This instruction show you guide on how to use JPRO diagnostic to do SCR performance…
Here is the instruction show you guide on how to remove and disassemble master cylinder…
This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 /…
Here is the instruction show you guide on how to repair P0731 incorrect 2nd gear ration…