Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.
There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.
Related Contents:
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnostic Kit DECOM for Deutz Engine
Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:
2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).
In the lower window following table is shown:
X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.
Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.
Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.
Notice:This function is available at Competence Class Level 2.
This instruction show guide on how to solve JCB JS140/205/215 machine trouble code P2280-00 air…
This instruction show you guide on how to do deactivation test for MANITOU MT6034 telehandlers…
This instruction show you guide on how to solve Liebherr machine ECU2 P1119-00 trouble code…
This instruction show you guide on how to solve Bobcat machine trouble code P18A5 suction…
The measured intake manifold pressure (signal from boost pressure sensor) is below the warning limit…
JCB 3CX 4CX Backhoe Loader engine throttle cable is routed from the L.H. side of the…