Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.
There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.
Related Contents:
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnostic Kit DECOM for Deutz Engine
Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:
2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).
In the lower window following table is shown:
X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.
Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.
Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.
Notice:This function is available at Competence Class Level 2.
This instruction show you guide on how to remove and install water pump for HINO…
JPRO 2025V3 CTIS Pressure test allow you to measure the pressure of a selected axle group…
This instruction show you guide on how to solve PCC2300 Powercommand HMI screen does not…
This instruction show you guide on how to solve AGCO machine SPN100 FMI 10 oil…
Here is the instruction show you guide on how to solve Valtra BH Series 140-210…
This instruction show you guide on how to use CAT ET 2025A to perform transmission…