Heavy Equipment Repair

How to Use Deutz SerDia2010 Trip Recorder Function?

Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.

There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.

Related Contents:

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Diagnostic Kit DECOM for Deutz Engine

 

 

Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:

 

2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]

Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).

In the lower window following table is shown:

X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.

Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.

 

Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.

Notice:This function is available at Competence Class Level 2.

auto

Recent Posts

How to Solve Allison 3000 & 4000 Gen5 Engine Trouble Code P0703

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…

1 day ago

How to Solve Fendt MT1149 Tractor SCR System Emptying Not Completed

Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…

1 week ago

How to Set Play Between Timing Pinion Teeth for CLAAS AXION 920 Tractor?

Here is the instruction show you guide on how to set play between timing pinion…

1 week ago

Perkins 1106D Generation Injector Data Incorrect Test Guide

Perkins 1106D Generation Injector Data Incorrect Test Guide   Preparations: Perkins EST 2024A & 2023A…

1 week ago

How to Solve Deutz EMR3 Engine Error 16/108/APSCD Trouble

This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…

1 week ago

Kubota L4701 High Pressure Relief Valve Pressure Checking

Here show guide on how to check high pressure relief valve pressure for Kubota L4701…

2 weeks ago