How to Use DMS-5 to Calibrate Swash Plate Angle

This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation

 

Procedures:

Swash Plate Angle Calibration

<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.

<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click ‘APPY’ after front pump calibration, and then click ‘APPLY’ again apply after rear pump calibration to save
the calibration value for each pump.
3. If the window displaying the value with red color, the pump is suspected to be defective so please contact Doosan regional service manager

Swash Plate Angle Calibration Setting before a test

 

Swash Plate Angle Calibration Process:

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save
the calibration value

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save the calibration value.

 

auto

Recent Posts

Valtra BH Series 140-210 Internal lateral Inertial Sensor Recalibration

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

3 hours ago

Bendix AutoVue 3G LDW System Driver Assistance Systems (DAS) Tests

JPRO 2025V3 Driver Assistance Systems (DAS) Tests allows the editing of configuration parameters.   Related Contents:…

4 days ago

How to Solve PCC2300 PowerCommand Membrane Buttons Not Functioning

This instruction show you guide on how to solve PCC2300 Powercommand Membrane buttons not working.…

1 week ago

How to Solve JCB JS140 Excavator C101E Fuel Level Empty Alarm Error?

This instruction show you guide on how to solve JCB JS140 excavator C101E-68 fuel level…

1 week ago

How to Solve AGCO Machine Oil Pressure Sensor Defect High and Low

Here is the instruction show you guide on how to solve AGCO machine trouble code…

2 weeks ago

Magneti Marelli 4CFR Ford and KIA ECM Pinout

Vehicles: Eco Esporte, Fiesta and Ka.   More ECU PINOUT Components: ECU Modules Repair Pinpout…

2 weeks ago