Categories: Excavator Repair

How to Use DMS-5 to Calibrate Swash Plate Angle

This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation

 

Procedures:

Swash Plate Angle Calibration

<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.

<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click ‘APPY’ after front pump calibration, and then click ‘APPLY’ again apply after rear pump calibration to save
the calibration value for each pump.
3. If the window displaying the value with red color, the pump is suspected to be defective so please contact Doosan regional service manager

Swash Plate Angle Calibration Setting before a test

 

Swash Plate Angle Calibration Process:

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save
the calibration value

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save the calibration value.

 

auto

Recent Posts

JCB JS140 Excavator C130C-13 Spool Brake Solenoid Open Circuit Solution

This instruction show you guide on how to solve spool brake solenoid open circuit for…

6 hours ago

Perkins 400A 400D Industrial Engine Crankshaft Rear Seal Remove and Install

This instruction show you guide on how to remove and install crankshaft rear seal for…

3 days ago

JPRO Diagnostic Software SCR Performance and System Test on Cummings

This instruction show you guide on how to use JPRO diagnostic to do SCR performance…

6 days ago

Yale ERP15-20VT G807 Forklift Truck Master Cylinder Removal and Disassemble Guide

Here is the instruction show you guide on how to remove and disassemble master cylinder…

1 week ago

How to Solve Deutz EMR3 71 / 2791 / EGRCD_SigNpl Error?

This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 /…

2 weeks ago

How to Solve Allison 3000 & 4000 Gen5 P0731 Incorrect 2nd Gear Ratio?

Here is the instruction show you guide on how to repair P0731 incorrect 2nd gear ration…

2 weeks ago