Categories: Excavator Repair

How to Use DMS-5 to Calibrate Swash Plate Angle

This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation

 

Procedures:

Swash Plate Angle Calibration

<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.

<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click ‘APPY’ after front pump calibration, and then click ‘APPLY’ again apply after rear pump calibration to save
the calibration value for each pump.
3. If the window displaying the value with red color, the pump is suspected to be defective so please contact Doosan regional service manager

Swash Plate Angle Calibration Setting before a test

 

Swash Plate Angle Calibration Process:

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save
the calibration value

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save the calibration value.

 

auto

Recent Posts

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

23 hours ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

2 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

3 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

4 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

5 days ago

How to Perform Relative Cylinder Compression Test for Detroit GHG17 Engine

This illustration show you how to use Detroit Diesel Diagnostic Link diagnostic software to do…

6 days ago