HINO DX3 CAN Bus Connection Check function is used to investigate the disconnected point of the ECU.
Related Contents:
JPRO DLA+ 2.0 Adapter /Nexiq USB2 Diagnostic Adapter
2024.03 HINO Diagnostic Explorer DX3/DX2 Diagnostic Software Free Download
HINO Trucks EPC Electronic Parts Catalog 2018 2016 Free Download
Procedures:
1.Select CAN bus connection check on the System Selection screen.
(System selection screen)
2.The on-board system list is displayed. Click or press the [Start] button.
(CAN Bus connection check screen)
3.CAN bus diagnosis with ECU starts.
(CAN Bus connection check screen)
[Reference]
• The number of communication failure DTCs indicates the number of communication failure DTCs detected for each system;simultaneously the communication failure system’s DTCs are highlighted line by line.
• The connection state indicates the connection state for each system.
When the connection is confirmed, ✓ is displayed; if not, × is displayed.
• Click the information icon to display the CAN bus diagnostic information for each ECU.
4.Click or press the [Stop] button to exit the CAN bus diagnosis with ECU.
(CAN Bus connection check screen)
More case for HINO please refer to:HINO Trouble Repair.
This instruction show you guide on how to solve Doosan Stage V machine U0632 timeout…
This instruction show you guide on how travel and adjust park brake piston for CASE…
Here is the instruction show you guide on how to replace purge valve for Fendit…
Here is the instruction show you guide on how to JCB machine SPN 102,FMI 1…
This instruction show you guide on how to install preconcave for CLAAS Lexion 480 combine…
This instruction show you guide on how to solve Deutz EMR3 trouble code 78/ 190 EngMOfsCaSCrS Speed…