Categories: Auto Repair

How to Use Multiecuscan to Diagnose Fiat Stilo 1.9 JTD

This instruction original from Multiecuscan official case,it show you Multiscanecu connect to the engine control module of Fiat Stilo 1.9 JTD,then check for errors and check some live data.

 

Preparations:

Multiecuscan V4.5 V4.2 V4.0 V3.8 Free Download

How to Install Crack Multiecuscan Software (Registered)

 

Procedures:

Step 1: Connect the interface to the computer and to the OBD port of the vehicle.

Step 2: Select make, model, version and control module.

Step 3: Click button “Connect” (or press F10 on your keyboard). Multiecuscan will start connecting to your car.

Step 4: After successful connection Multiecuscan will show the Info screen

Step 5: Now we can go to the Errors screen and check for stored fault codes.

As you can see this control module reports 2 errors. Actually, I intentionally created these 2 errors by unplugging the MAF connector while the engine was working.

In the lower left window you can see details about the conditions when the error code was detected.Anyway, since we know that we have fixed the reason for the errors (I plugged the connector back), we can clear the errors.

Simply click the “Clear Errors” button (or press F10 on your keyboard) and Multiecuscan will clear those errors.

Step 6: Now we can go to the Parameters screen and check some live data.

Here we selected 3 parameters – Engine speed, Total fuel quantity and Injection time.

Multiecuscan marks the selected parameters in red and begins to show live data for these 3 parameters.

Step 7: Now we can go to the Graph screen and make a CSV recording of the live data.

On this screen we see the parameters which we already selected on the Parameters screen.

The left part of the screen shows live data for our parameters. It also monitors min/max values during the data recording.

You can click the Start/Stop button to create a recording.

Step 8: Now we can go to the Actuators screen and make some tests.

We see all tests which are available for this control module. We will select “Fan 1st speed” and execute it.

We press F10 and Multiecuscan will start executing this test. The engine cooling fan starts to work at low speed for a few seconds.

When the test has finished Multiecuscan will show message “Completed”.

Step 9: Disconnect from engine control module. You can disconnect from the control module and return to Multiecuscan at any time by pressing F11.

auto

Recent Posts

Volvo and Mack EPA 10 Engine Hydrocarbon Dosing Control Valve Test by JPRO

This instruction show you guide on how to perform hydrocarbon dosing control valve test for…

2 days ago

Fendt Tractor SPN 100 FMI 31 Oil Pressure Sensor Defect Solution

This instruction show you guide on how to solve Fendt tractor SPN 100 FMI 31…

4 days ago

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure   Related Contents: 2024.06 Detroit Diesel…

6 days ago

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.…

7 days ago

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout   Vehicles: Monza, Kadett and…

1 week ago

How to Remove Oil Pressure Regulation Valve for CLAAS AXION 950

This illustration show you guide on how to remove oil pressure regulation valve for CLAAS…

1 week ago