How to Use Scania XCOM Clear/Reset Memory Areas

This instruction show ou guide on how to use Scania XCOM software to reset/clear memory areas.And please follow below operations:

 

Preparations:

Scania XCOM V2.30 V2.27 Dongle Emulator Free Download

How to Install Scania XCOM V2.30 Diagnostic Software

 

Steps:

1) Connect to CAN (see use case “Connect to CAN”)

2) Open the ”Clear” form for the related ECU. This is done either by expanding the ECU node in explorer tree and double clicking on the ”Clear” function/data node or by selecting the menu choice ECUs->(the EcuName)->Clear. The Configuration form is displayed. Example:

3) Select the area that is to be programmed by making the check mark visible for the name of the area in the list box.

4) Press the ”Clear selected areas” button to reset the data area.

5) When the button is pushed a dialog is displayed to confirm the operation:

6) Press ”Yes” to start the reset sequence. An ECU reset will be performed when the clear is done.

7) When the sequence is complete a dialog is displayed to report the result:

 

DCMN memory area

To clear (reset) DCMN data areas, perform the following steps.

1) Connect to CAN (see use case “Connect to CAN”) if not already connected.

2) Open the ”Duty Cycle Data” form for the related ECU. This is done either by expanding the ECU node in explorer tree and double clicking on the ”Duty Cycle Data” function/data node or by selecting the menu choice ECUs->(the EcuName)->Duty Cycle Data. The ”Duty Cycle Data” form is displayed

3) Select the areas that are to be cleared by putting the check mark in the boxes of the names in the list box.

4) Clear the areas by pressing the ”Reset” button.

5) The application will erase the areas and display the result in the main form”s status window.

6) The sequence is now complete

 

OPC4/RET1 statistic tables

To clear the OPC/RET statistics tables, perform the following steps.

1) Connect to CAN (see use case “Connect to CAN”) if not already connected.

2) Open the ”Statistics” form for the a OPC or RET.

3) Click the “Clear statistics tables” to clear the tables.

4) A query dialog will be displayed to confirm the action.

5) Press ‘Yes’ to proceed and ‘No’ to abort the sequence.

6) The result of the action is displayed in the main form’s status window.

7) The sequence is now complete.

 

auto

Recent Posts

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

14 hours ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

2 days ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

2 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

4 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

5 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

6 days ago