The measured boost pressure drops below the alarm level during operation.
Possible causes are:
The boost air piping is leaking.
The exhaust line is partially blocked. (DOC/SCR)
The turbocharger is defective.
The engine is mechanically defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. Engine power will be reduced (Degradation Level 2). The CAN message indicates active fault.
Solution
Find the cause for the low boost pressure indication:
Check the boost air system tightness (the piping, the intercooler).
Inspect the exhaust line for possible blockage. Remove SCR dosing module from the exhaust line and check the mixer condition.
Check the mechanical condition of the engine.
Check the condition of the turbo charger. Check fresh air intake and air filter pressure alarm switch being in-active.
This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…