Categories: Excavator Repair

JCB Machine Aftertreatment ECU Programming Guide

It requires you to program aftertreatment ECU after replacing new aftertreatment ECU for JCB machine.So here is a guide on how to use JCB ServiceMaster 4 diagnostic software to do aftertreatment ECU programming.

 

Preparations:

2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

Procedures:

1.Make sure that the machine is switched off and isolated. Install the new Aftertreatment ECU.

2.Make sure the machine is switched on, immobiliser deactivated (immobiliser code entered or transponder key present) and ServiceMaster is connected. Refer to Activating/Deactivating/Resetting Engine Immobiliser

3.Navigate to the relevant machine engine setup tool.

4.The DCU ESN and DCU software version boxes will be empty. Select the Restore Defaults button

5.The following warning will appear. Select Yes.

6.When the flash has completed, the following box will appear. Switch off the machine and wait for at least 2 minutes before performing any further operations on the machine.

7.Switch on the machine and open the engine setup tool. The tool should display the engine information previously written. The DCU ESN box will now populated.

8.The DCU will require flashing. Refer to Updating Aftertreatment ECU Software.

More topics for JCB machine,please refer to:JCB Machine Trouble Repair.

auto

Recent Posts

Volvo and Mack EPA 10 Engine Hydrocarbon Dosing Control Valve Test by JPRO

This instruction show you guide on how to perform hydrocarbon dosing control valve test for…

3 days ago

Fendt Tractor SPN 100 FMI 31 Oil Pressure Sensor Defect Solution

This instruction show you guide on how to solve Fendt tractor SPN 100 FMI 31…

5 days ago

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure

Detroit GHG17 Heavy Duty Engine Piston Protrusion Measurement Procedure   Related Contents: 2024.06 Detroit Diesel…

7 days ago

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.…

1 week ago

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout

Monza, Kadett and Ipanema Multec 700 GM ECU Components Pinout   Vehicles: Monza, Kadett and…

1 week ago

How to Remove Oil Pressure Regulation Valve for CLAAS AXION 950

This illustration show you guide on how to remove oil pressure regulation valve for CLAAS…

1 week ago