Here is the instruction show you guide on how to solve JCB Tier 4 engine SPN 1321, FMI 3 and SPN 1321, FMI 6 start reply high side voltage/current above normal.
Related Contents:
WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download
2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11
2017 JCB Parts Plus+ and Repair Service Manual Free Download
Start Relay High Side Voltage Above Normal
Description
The start relay high side voltage is above the normal operating range.
Possible causes are:
The start relay wiring is defective.
The start relay is defective
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
Check the operation with another start relay to see if the relay is defective.
Start Relay High Side Current Above Normal
Description
The start relay high side current is above the normal operating range.
Possible causes are:
The start relay wiring is defective.
The start relay is defective
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
Check the operation with another start relay to see if the relay is defective.
More repair case for JCB,please refer to:JCB Trouble Repair
This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…
Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…
Here is the instruction show you guide on how to set play between timing pinion…
Perkins 1106D Generation Injector Data Incorrect Test Guide Preparations: Perkins EST 2024A & 2023A…
This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…
Here show guide on how to check high pressure relief valve pressure for Kubota L4701…