Heavy Equipment Repair

JCB Tier 4 Engine Start Relay High Side Voltage and Current Above Normal

Here is the instruction show you guide on how to solve JCB Tier 4 engine SPN 1321, FMI 3 and SPN 1321, FMI 6 start reply high side voltage/current above normal.

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

 

Start Relay High Side Voltage Above Normal

Description

The start relay high side voltage is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

 

 

Start Relay High Side Current Above Normal

Description

The start relay high side current is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

More repair case for JCB,please refer to:JCB Trouble Repair

auto

Recent Posts

Jungheinrich Junior AME13 Spring-Loaded Brake Electrical Connection Removal Guide

It is necessary step to remove electrical connection cable before you do disassemble or some…

16 hours ago

How to Use Nexiq eTechnician Function Test?

Nexiq eTechnician provides a number of special tests to assist you with your vehicle diagnostic…

3 days ago

JCB JS140 Excavator P0523-68 Engine Oil Pressure Low Solution

Here car-auto-repair.com show you guide on how to repair JCB JS140 excavator P0523-68 trouble code…

4 days ago

Volvo Version 3 and 4 Truck Oil Pressure Test by Volvo Techtool

Here is the instruction show you guide on how to use Volvo TECHTOOL and VOCOM adapter to…

5 days ago

How to Solve Allison 3000 & 4000 Gen5 P071A Neutral at Stop Input Failed ON

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 transmission…

7 days ago

Mack and Volvo EPA13 GHG17 Engine NOx Conversion Monitor Test

This instruction show you guide on how to use JPRO TO perform Mack and Volvo…

1 week ago