This instruction show you guide on how to repair JCB stage V Tier 4 Boost pressure sensor voltage above normal or open circuit problem.
Related Content:
WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download
2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11
2017 JCB Parts Plus+ and Repair Service Manual Free Download
Description
The measured boost pressure signal is above the normal operating range (> 4,9 V).
Possible causes are:
The boost pressure sensor wiring is defective. (Shorted to high source or an open circuit.)
The boost pressure sensor power supply is not correct.
The boost pressure sensor is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. Engine power will be reduced (Degradation Level 1). The CAN message indicates active fault. The engine functions dependent on the boost pressure are not active.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
Check the boost pressure sensor wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
Check the 5 V power supply to the sensor.
Check the operation with another boost pressure sensor to see if the boost pressure sensor is defective.
More repair case for JCB,please refer to:JCB Trouble Repair
This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 engine…
Here is the illustration show you guide on how to solve Fendt MT1149 tractor SCR…
Here is the instruction show you guide on how to set play between timing pinion…
Perkins 1106D Generation Injector Data Incorrect Test Guide Preparations: Perkins EST 2024A & 2023A…
This instruction show you guide on how to solve Deutz EMR3 engine error 16/108/APSCD trouble…
Here show guide on how to check high pressure relief valve pressure for Kubota L4701…