Heavy Equipment Repair

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You are advised to use this function when adding or removing:

 

One electrohydraulic valve at the rear of the tractor, or

The electrohydraulic valves at the front of the tractor, or

The front linkage electrohydraulic valve.

 

Preparations:

AGCO EDT 2024

AGCO 2×4 CANUSB

 

 

Important:

For modifications to the hydraulic configuration, the label codes for the linkage controller must be updated.

 

Procedure

1 Select “Change the identifier of all head valves” A then “Start” B

2 Select “the maximum number valve connected on the bus” C

3 Select the maximum number of electrohydraulic spool valves at the front of the tractor D

No electrohydraulic spool valves at the front = 0

With 1 electrohydraulic spool valve at the front = 1

With 2 electrohydraulic spool valves at the front = 2

4 Specify whether the tractor has a front linkage E

Without front linkage = 0

With front linkage = 1

5 Disconnect all electrohydraulic valves from the tractor then “Validate” F

6 Connect rear electrohydraulic spool valve no. 1 using connector X33 – Connector for the electrohydraulic spool-valves supply and X240 – Termination connector for an electrohydraulic spool valve (120-ohm resistor).Select “Refresh” G once the connection to valve no. 1 has been established

 

7 The following message appears: “Auxiliary spool valve no. 1 is correctly configured”. Press “Validate” H to move on to the next electrohydraulic valve.When changing the identification number of the valve, it may be necessary to switch off the ignition.

8 Repeat the above configuration steps for all the valves, following the procedure set out in the diagnostic tool and the sequence of electrohydraulic spool valves.

Rear spool valve no. 1 = 1

Rear spool valve no. 2 = 2

Rear spool valve no. 3 = 3

Rear spool valve no. 4 = 4

Rear spool valve no. 5 = 5

Rear spool valve no. 6 = 6

Front spool valve no. 1 = 7

Front spool valve no. 2 = 8

Front linkage valve = 9

9 Once the procedure for configuring the valves is complete, reconnect all the electrohydraulic spool valves for the tractor to their respective connectors/harnesses

 

AGCO EDT Electronic Diagnostic Tool 1.128 Diagnostic Software

 

auto

Recent Posts

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

3 days ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

1 week ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

2 weeks ago

How to Adjust Cruise Control Release Linkage for Kubota L3901 Excavator?

This is instruction show you guide on how to adjust cruise control release linkage for…

2 weeks ago

How to do Perform Cylinder Cut-off Test for Massey Ferguson Tractor

This instruction show you guide on how to use AGCO EDT diagnostic software to perform…

2 weeks ago

Hitachi EX5600-7B Folding Stairway and Surrounding Parts Removal Guide

This instruction show you guide on how to remove folding stairway and surrounding part for…

3 weeks ago