Mercedes Benz W204 Tail Lights Retrofit Coding by Vediamo

In this instruction,i will show you guide on how to do coding for Mercedes Benz W204 tail lights retrofit by Vediamo software. And for more Benz Vediamo projects,please check here:Benz Vediamo Projects

 

Preparations:

Benz Vediamo Software Free Download

 

Vehicle information:

Mercedes Benz C-Class W204 with original tail lights configuration

 

If you install tail light directly,you will find tail lights can not work correctly.

Dashboard show tail lights trouble and fog lights trouble etc

 

For this trouble,you can not use common diagnostic tool to solve,it must be use Vediamo software to code the SAM.

 

Benz 2006-2009 Tail Light Retrofit Coding Procedures:

Access W204 SAM ECU

Enter “Variant Coding” to select “Parameter Lichtfunktion”

Check item at “Current Coding” section

Select “BrkLmpTailLmpLed_b”,and change value to “Bulb”

And then select “TailLmpEmergBrkVoltLevel”,and change value from “4V” to “6V”

Now select below two options,and disable them.It can solve tail light all time problem

Select “SmlmpinEnable_b” value to “nicht freigegeben”

And select “SmlmpOutEnable_b” value to “freigegeben”

Select “FogLmpSmLmpLed_b”,and change it to “LED”

For parking lights

Now click “ECU-Coding” button to code the value you changed before

 

Benz 2010- Tail Light Retrofit Coding Procedures:

Here only show you the different options

Benz 2010,you can code for SAM function to modify the light intensity

More voltage range for brake light min selection 0.1V

Tail Lights

 

For coding procedures is same as 2006-2009.

auto

Recent Posts

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

17 hours ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

2 days ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

3 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

4 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

5 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

6 days ago