Special tools, Material, Spare parts

 

Replacing oil separator element
1 Remove cover (2) with O-ring (3).
2 Remove filter element (1) from housing (4).
3 Insert new filter element in housing (4).
4 Install cover (2) with new O-ring.

5 Use torque wrench to tighten the screws of cover (2) to the specified torque.

6 Replace further oil separator elements in the same way.

 

Checking diaphragm
1 Remove cover (4).
2 Remove spring (5), gasket (2) and diaphragm (3).
3 Check diaphragm (3) for damage, fit new diaphragm if used one is damaged.
4 Install diaphragm (3) on housing (1).
5 Install new seal (2) and spring (5) together with cover (4).

 

6 Use torque wrench to tighten the screws of cover (4) to the specified torque.

7 Check diaphragms in further oil separators in the same way.

 

 

auto

Recent Posts

How to Use Cat ET 2024A to Perform Fuel Rail Pressure Test

CAT ET 2024A Fuel Rail Pressure Test function checks for leaks on all hydraulic components.…

16 hours ago

How to Use Ktag to Clone ECU for BMW 5 Series MEVD17

It is necessary to clone ECU data when you need replace a used ECU for…

2 days ago

MTU 12V 4000 Engine Valve Clearance,Check and Adjustment

It is necessary to clear valve for MTU 12V 40000 when you do life maintenance,here…

3 days ago

Doosan Engine Start Failed Error Code P0A0F Solution

Doosan engine failed start problem is a universal error,here show the guide on how to…

4 days ago

QSK60 G CM2358 Engine Oil Rifle Sensor Voltage Above Normal 135

QSK60 G CM2358 Fault code 135 Engine Oil Rifle Pressure 1 Sensor Circuit - Voltage…

5 days ago

PCC1302 PowerCommand Engine Fault Code 1471 – High AC Current Solution

Here is the instruction show you guide on how to solve PowerCommand Engine/generator fault code…

6 days ago